Study of zearalenone by high performance liquid chromatography with fluorescentce detection
Haibin Zhang
Abstract
Haibin Zhang
Abstract
High performance liquid chromatography equipped with fluorescence detection(HPLC-FLD)was established for the detection of zearalenone(ZEA or F-2 toxin)in feedstuff.The extracts were cleaned-up through chromatographic column and commercially available immunoaffinity columns.The present study optimized and set up that chromatographic condition that extracting solution was methylalcohol with water and acetonitrile(10∶46∶44),excitation wavelength 274 nm,emission wavelength 440 nm,flow rate(0.6 mL·min-1),and column temperature(25 ℃).The linear correlation was well between 0.025-0.8 μg·mL-1.The coefficient of recovery was 88.74% and the dection limit was 5.7 μg·L-1.The recoveries from spliked feedstuffs samples with toxin levers from 0.025 to 0.8 μg·mL-1ranged from 83.91% to 88.74% with relative standard deviation generally lower than 4.01%.It suggested that HPLC-FLD was precise and sensitive and suitable for the quantitation of F-2 toxin.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
High performance liquid chromatography equipped with fluorescence detection(HPLC-FLD)was established for the detection of zearalenone(ZEA or F-2 toxin)in feedstuff.The extracts were cleaned-up through chromatographic column and commercially available immunoaffinity columns.The present study optimized and set up that chromatographic condition that extracting solution was methylalcohol with water and acetonitrile(10∶46∶44),excitation wavelength 274 nm,emission wavelength 440 nm,flow rate(0.6 mL·min-1),and column temperature(25 ℃).The linear correlation was well between 0.025-0.8 μg·mL-1.The coefficient of recovery was 88.74% and the dection limit was 5.7 μg·L-1.The recoveries from spliked feedstuffs samples with toxin levers from 0.025 to 0.8 μg·mL-1ranged from 83.91% to 88.74% with relative standard deviation generally lower than 4.01%.It suggested that HPLC-FLD was precise and sensitive and suitable for the quantitation of F-2 toxin.
Key concepts: Zearalenone, Chromatography, High-performance liquid chromatography, Detection limit, Chemistry, Excitation wavelength, Acetonitrile, Correlation coefficient