2011Unpublished venueRequires access

Study of zearalenone by high performance liquid chromatography with fluorescentce detection

Haibin Zhang

Open publisher page 0 citations

Abstract

High performance liquid chromatography equipped with fluorescence detection(HPLC-FLD)was established for the detection of zearalenone(ZEA or F-2 toxin)in feedstuff.The extracts were cleaned-up through chromatographic column and commercially available immunoaffinity columns.The present study optimized and set up that chromatographic condition that extracting solution was methylalcohol with water and acetonitrile(10∶46∶44),excitation wavelength 274 nm,emission wavelength 440 nm,flow rate(0.6 mL·min-1),and column temperature(25 ℃).The linear correlation was well between 0.025-0.8 μg·mL-1.The coefficient of recovery was 88.74% and the dection limit was 5.7 μg·L-1.The recoveries from spliked feedstuffs samples with toxin levers from 0.025 to 0.8 μg·mL-1ranged from 83.91% to 88.74% with relative standard deviation generally lower than 4.01%.It suggested that HPLC-FLD was precise and sensitive and suitable for the quantitation of F-2 toxin.

About this research paper

What this paper is about

High performance liquid chromatography equipped with fluorescence detection(HPLC-FLD)was established for the detection of zearalenone(ZEA or F-2 toxin)in feedstuff.The extracts were cleaned-up through chromatographic column and commercially available immunoaffinity columns.The present study optimized and set up that chromatographic condition that extracting solution was methylalcohol with water and acetonitrile(10∶46∶44),excitation wavelength 274 nm,emission wavelength 440 nm,flow rate(0.6 mL·min-1),and column temperature(25 ℃).The linear correlation was well between 0.025-0.8 μg·mL-1.The coefficient of recovery was 88.74% and the dection limit was 5.7 μg·L-1.The recoveries from spliked feedstuffs samples with toxin levers from 0.025 to 0.8 μg·mL-1ranged from 83.91% to 88.74% with relative standard deviation generally lower than 4.01%.It suggested that HPLC-FLD was precise and sensitive and suitable for the quantitation of F-2 toxin.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High performance liquid chromatography equipped with fluorescence detection(HPLC-FLD)was established for the detection of zearalenone(ZEA or F-2 toxin)in feedstuff.The extracts were cleaned-up through chromatographic column and commercially available immunoaffinity columns.The present study optimized and set up that chromatographic condition that extracting solution was methylalcohol with water and acetonitrile(10∶46∶44),excitation wavelength 274 nm,emission wavelength 440 nm,flow rate(0.6 mL·min-1),and column temperature(25 ℃).The linear correlation was well between 0.025-0.8 μg·mL-1.The coefficient of recovery was 88.74% and the dection limit was 5.7 μg·L-1.The recoveries from spliked feedstuffs samples with toxin levers from 0.025 to 0.8 μg·mL-1ranged from 83.91% to 88.74% with relative standard deviation generally lower than 4.01%.It suggested that HPLC-FLD was precise and sensitive and suitable for the quantitation of F-2 toxin.

Key concepts: Zearalenone, Chromatography, High-performance liquid chromatography, Detection limit, Chemistry, Excitation wavelength, Acetonitrile, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of zearalenone by high performance liquid chromatography with fluorescentce detection — Research Paper | ScholarLens