Measurement of Crack Length by Ultrasonic Attenuation Coefficient
정남용, 박성일
Abstract
정남용, 박성일
Abstract
In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally. From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally. From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.
Key concepts: Attenuation, Materials science, Attenuation coefficient, Ultrasonic sensor, Cantilever, Acoustics, Ultrasonic attenuation, Composite material