2010•Misr journal of agricultural engineeringOpen access

EVAPORATIVE COOLING AND TEMPERATURE INSIDE GREENHOUSE UNDER HOT ARID AIR CONDITIONS

G. M. Abdel-Rahman, Ahmad O. Al-Amoudi

Open full text 0 citations

Abstract

The aim of the present work is to study the effect of evaporative cooling system for greenhouse under humid and hot weather. A gable roof design greenhouse was covered with old fiberglass glazing for more than 15 years was used. The experiment was carried out for 26 days of continuous data measuring, starting from June 8 to July 3 of year 2010 where the highest outside air temperature was obtained. Greenhouse dimension was 24 m. long, 10 m. width and 4 m. height. The results show that the highest difference of about 10-11 oC. was between cooling pad section and outside air temperature. Meanwhile, the lowest temperature differences were 2-6 oC. between middle section of the greenhouse and cooling pad section. The maximum value of sensible heat transfer was 53 kJ/s between outside and evaporative pad.

Open-access reader

About this research paper

What this paper is about

The aim of the present work is to study the effect of evaporative cooling system for greenhouse under humid and hot weather. A gable roof design greenhouse was covered with old fiberglass glazing for more than 15 years was used. The experiment was carried out for 26 days of continuous data measuring, starting from June 8 to July 3 of year 2010 where the highest outside air temperature was obtained. Greenhouse dimension was 24 m. long, 10 m. width and 4 m. height. The results show that the highest difference of about 10-11 oC. was between cooling pad section and outside air temperature. Meanwhile, the lowest temperature differences were 2-6 oC. between middle section of the greenhouse and cooling pad section. The maximum value of sensible heat transfer was 53 kJ/s between outside and evaporative pad.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of the present work is to study the effect of evaporative cooling system for greenhouse under humid and hot weather. A gable roof design greenhouse was covered with old fiberglass glazing for more than 15 years was used. The experiment was carried out for 26 days of continuous data measuring, starting from June 8 to July 3 of year 2010 where the highest outside air temperature was obtained. Greenhouse dimension was 24 m. long, 10 m. width and 4 m. height. The results show that the highest difference of about 10-11 oC. was between cooling pad section and outside air temperature. Meanwhile, the lowest temperature differences were 2-6 oC. between middle section of the greenhouse and cooling pad section. The maximum value of sensible heat transfer was 53 kJ/s between outside and evaporative pad.

Key concepts: Evaporative cooler, Greenhouse, Environmental science, Atmospheric sciences, Air temperature, Glazing, Heat transfer, Meteorology

Related papers

Back to paper searchBrowse research topicsOriginal source
EVAPORATIVE COOLING AND TEMPERATURE INSIDE GREENHOUSE UNDER HOT ARID AIR CONDITIONS — Research Paper | ScholarLens