The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation
Zongli Hu, Chunlin Chen, Min Sun, Rongdi Yuan, Jian Ye
Abstract
Open-access reader
Zongli Hu, Chunlin Chen, Min Sun, Rongdi Yuan, Jian Ye
Abstract
Open-access reader
Purpose. To confirm the relationship between anterior chamber angle (ACA) and intraocular pressure (IOP) early after V4c implantable collamer lens (ICL) implantation. Methods. Patients were assigned to two groups: (1) right eyes (control group) and (2) left eyes (experimental group), with miosis conducted immediately after ICL implantation in the left eyes. IOP, angle opening distance (AOD), trabecular-iris angle (TIA), and pupil diameter (PD) were compared between two groups at postoperative hours 1, 2, and 24. The relationship between ACA, PD, and IOP was analyzed by multiple linear regression. Result. Thirty-six eyes of 18 patients were enrolled. The prevalence of ocular hypertension (OHT, defined as IOP ≥ 21 mmHg) was 61.11% and 16.67% in the right and left eyes, respectively, ( χ2 = 7.481, p=0.006 ). At postoperative hours 1 and 2, IOP and PD were significantly higher p<0.001 in the right eyes, and TIA and AOD were significantly lower p<0.05 in the right eyes than in the left eyes. There was no significant difference at 24 h postoperative in these parameters. After the right eye ICL implantation, the changes of AOD 500 and PD were both linearly correlated with postoperative IOP change (β = −23.707 and 1.731, respectively; p = 0.013 and 0.002, respectively). Conclusion. The ACA was significantly narrowed immediately after V4c ICL implantation. There was a negative linear correlation between ACA and early IOP and a positive linear correlation between PD and early IOP. We recommend the use of intracameral miotics immediately after V4c ICL implantation to reduce the incidence of IOP spikes.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose. To confirm the relationship between anterior chamber angle (ACA) and intraocular pressure (IOP) early after V4c implantable collamer lens (ICL) implantation. Methods. Patients were assigned to two groups: (1) right eyes (control group) and (2) left eyes (experimental group), with miosis conducted immediately after ICL implantation in the left eyes. IOP, angle opening distance (AOD), trabecular-iris angle (TIA), and pupil diameter (PD) were compared between two groups at postoperative hours 1, 2, and 24. The relationship between ACA, PD, and IOP was analyzed by multiple linear regression. Result. Thirty-six eyes of 18 patients were enrolled. The prevalence of ocular hypertension (OHT, defined as IOP ≥ 21 mmHg) was 61.11% and 16.67% in the right and left eyes, respectively, ( χ2 = 7.481, p=0.006 ). At postoperative hours 1 and 2, IOP and PD were significantly higher p<0.001 in the right eyes, and TIA and AOD were significantly lower p<0.05 in the right eyes than in the left eyes. There was no significant difference at 24 h postoperative in these parameters. After the right eye ICL implantation, the changes of AOD 500 and PD were both linearly correlated with postoperative IOP change (β = −23.707 and 1.731, respectively; p = 0.013 and 0.002, respectively). Conclusion. The ACA was significantly narrowed immediately after V4c ICL implantation. There was a negative linear correlation between ACA and early IOP and a positive linear correlation between PD and early IOP. We recommend the use of intracameral miotics immediately after V4c ICL implantation to reduce the incidence of IOP spikes.
Key concepts: Medicine, Intraocular pressure, Ophthalmology, Algorithm, Mathematics