2000Microscopy and MicroanalysisRequires access

Use of the Low Voltage Transmission Electron Microscope with Biological Specimens: A Feasibility Study

William P. Sharp, Eva Coufalova, A. Delong, Vladimı́r Kolařı́k, Robert W. Roberson, IST Tsong

Open publisher page 0 citations

Abstract

Abstract Biological transmission electron microscopy (TEM) has evolved over the past 50 to 60 years in concert with the instrumentation available. As beam acceleration energies have increased to 100-200 keV, specimen preparation protocols have been modified and tailored to fit the capabilities and constraints of new TEMs. Higher voltage allows improved resolution, (Fig. 1) but as acceleration voltage increases, contrast decreases. Vacuum levels required for conventional TEM prevent specimen contamination which protects specimen details from being obscured, but lower contrast requires heavy metal post staining which may lead to specimen contamination. Specimen thickness can increase with higher voltage (up to lOOnm at 200keV) because penetration is much increased, however, the chance of specimen - electron interaction of the type that causes heat build-up and specimen damage increases rapidly with thickness. It seems that these limitations and others must be tolerated in order to enjoy the obvious advantages of TEM.

About this research paper

What this paper is about

Abstract Biological transmission electron microscopy (TEM) has evolved over the past 50 to 60 years in concert with the instrumentation available. As beam acceleration energies have increased to 100-200 keV, specimen preparation protocols have been modified and tailored to fit the capabilities and constraints of new TEMs. Higher voltage allows improved resolution, (Fig. 1) but as acceleration voltage increases, contrast decreases. Vacuum levels required for conventional TEM prevent specimen contamination which protects specimen details from being obscured, but lower contrast requires heavy metal post staining which may lead to specimen contamination. Specimen thickness can increase with higher voltage (up to lOOnm at 200keV) because penetration is much increased, however, the chance of specimen - electron interaction of the type that causes heat build-up and specimen damage increases rapidly with thickness. It seems that these limitations and others must be tolerated in order to enjoy the obvious advantages of TEM.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Biological transmission electron microscopy (TEM) has evolved over the past 50 to 60 years in concert with the instrumentation available. As beam acceleration energies have increased to 100-200 keV, specimen preparation protocols have been modified and tailored to fit the capabilities and constraints of new TEMs. Higher voltage allows improved resolution, (Fig. 1) but as acceleration voltage increases, contrast decreases. Vacuum levels required for conventional TEM prevent specimen contamination which protects specimen details from being obscured, but lower contrast requires heavy metal post staining which may lead to specimen contamination. Specimen thickness can increase with higher voltage (up to lOOnm at 200keV) because penetration is much increased, however, the chance of specimen - electron interaction of the type that causes heat build-up and specimen damage increases rapidly with thickness. It seems that these limitations and others must be tolerated in order to enjoy the obvious advantages of TEM.

Key concepts: Transmission electron microscopy, Materials science, Electron microscope, Conventional transmission electron microscope, Transmission (telecommunications), Low-voltage electron microscope, Voltage, Microscope

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of the Low Voltage Transmission Electron Microscope with Biological Specimens: A Feasibility Study — Research Paper | ScholarLens