Thermal comfort evaluation in an educational building with air conditioning located in the warm tropical climate of Colombia
M Balbis-Morejon, A Noya-Sambrano
Abstract
Open-access reader
M Balbis-Morejon, A Noya-Sambrano
Abstract
Open-access reader
Abstract The objective of this work is to evaluate the perception of thermal comfort that students have in building 10 of the Universidad de la Costa located in the city of Barranquilla. For the investigation the methods for the thermal comfort evaluation are analyzed, selecting the Steady-State methodology of Fanger according to the ASHRAE 55 Standard. With the application of the surveys, the thermal sensation that the students had in the building was evaluated, which was preferably fresh and thermal acceptability where 87% responded satisfactorily to indoor climate conditions in classrooms. It was also obtained that the perception of inner thermal comfort is between 21.1 ° C and 23 ° C of temperature. With the results obtained, recommendations are issued to ensure that students feel thermal comfort and the proper regulation of air conditioning systems.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract The objective of this work is to evaluate the perception of thermal comfort that students have in building 10 of the Universidad de la Costa located in the city of Barranquilla. For the investigation the methods for the thermal comfort evaluation are analyzed, selecting the Steady-State methodology of Fanger according to the ASHRAE 55 Standard. With the application of the surveys, the thermal sensation that the students had in the building was evaluated, which was preferably fresh and thermal acceptability where 87% responded satisfactorily to indoor climate conditions in classrooms. It was also obtained that the perception of inner thermal comfort is between 21.1 ° C and 23 ° C of temperature. With the results obtained, recommendations are issued to ensure that students feel thermal comfort and the proper regulation of air conditioning systems.
Key concepts: ASHRAE 90.1, Thermal comfort, Thermal sensation, Air conditioning, Architectural engineering, Tropical climate, Environmental science, Work (physics)