2004•Journal of Beijing Institute of TechnologyRequires access

Study on Thermal Comfort in Non-Air-Conditioned Buildings in Jiangsu and Zhejiang Provinces

JI Xiu-ling

Open publisher page 12 citations

Abstract

An investigation on thermal comfort of multitude in the environments without air-conditioning in Jiangsu and Zhejiang provinces was conducted in the summer, 2000 and 2001. The environments investigated are outside the American Society of Heating Refrigerating and Air Conditing Engineerings(ASHRAE) comfort zone. The results showed that the actual mean thermal sensation is lower than predicted mean vote (V_(pm)), about 0.64 V_(pm), and the upper limits of ET~*(t_e) acceptable by 80% of people is about 30 ℃, much higher than 26 ℃ recommended by the current ASHRAE standard. These facts reveal that people in those areas have adapted to such a climate and can endure heat in a certain degree, and verify that adaptation to the indoor environment may change human expectations and thermal sensations. Proper amendments to the current standard should be given according to actual conditions.

About this research paper

What this paper is about

An investigation on thermal comfort of multitude in the environments without air-conditioning in Jiangsu and Zhejiang provinces was conducted in the summer, 2000 and 2001. The environments investigated are outside the American Society of Heating Refrigerating and Air Conditing Engineerings(ASHRAE) comfort zone. The results showed that the actual mean thermal sensation is lower than predicted mean vote (V_(pm)), about 0.64 V_(pm), and the upper limits of ET~*(t_e) acceptable by 80% of people is about 30 ℃, much higher than 26 ℃ recommended by the current ASHRAE standard. These facts reveal that people in those areas have adapted to such a climate and can endure heat in a certain degree, and verify that adaptation to the indoor environment may change human expectations and thermal sensations. Proper amendments to the current standard should be given according to actual conditions.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An investigation on thermal comfort of multitude in the environments without air-conditioning in Jiangsu and Zhejiang provinces was conducted in the summer, 2000 and 2001. The environments investigated are outside the American Society of Heating Refrigerating and Air Conditing Engineerings(ASHRAE) comfort zone. The results showed that the actual mean thermal sensation is lower than predicted mean vote (V_(pm)), about 0.64 V_(pm), and the upper limits of ET~*(t_e) acceptable by 80% of people is about 30 ℃, much higher than 26 ℃ recommended by the current ASHRAE standard. These facts reveal that people in those areas have adapted to such a climate and can endure heat in a certain degree, and verify that adaptation to the indoor environment may change human expectations and thermal sensations. Proper amendments to the current standard should be given according to actual conditions.

Key concepts: ASHRAE 90.1, Thermal comfort, Thermal sensation, Environmental science, Air conditioning, Meteorology, Adaptation (eye), Architectural engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Thermal Comfort in Non-Air-Conditioned Buildings in Jiangsu and Zhejiang Provinces — Research Paper | ScholarLens