This paper deals with energy performances of a 440-kW (125-ton) air-conditioning factory-assembled water chiller with totally oil-free, variable speed centrifugal compressors and air-cooled condensers. The prototype was installed in Montreal (Eastern Canada) in a retrofit building with telecommunication equipment, process computers and other similar cooling charges. The non-standard part load values (NPLV) are calculated during a typical summer Canadian weather period. This study demonstrates that magnetic bearings, variable-speed compression and digital electronic controls achieve high compressor efficiencies with air-cooled water chillers. For the retrofit system having a very constant process cooling charge, the average seasonal NPLV is 49% lower as compared to previous existing conventional air-cooled chillers. The mechanical room noise is also significantly diminished, while the simple pay-back period is estimated at 3.5 years (without subsides) for a technical life of 25 year.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper deals with energy performances of a 440-kW (125-ton) air-conditioning factory-assembled water chiller with totally oil-free, variable speed centrifugal compressors and air-cooled condensers. The prototype was installed in Montreal (Eastern Canada) in a retrofit building with telecommunication equipment, process computers and other similar cooling charges. The non-standard part load values (NPLV) are calculated during a typical summer Canadian weather period. This study demonstrates that magnetic bearings, variable-speed compression and digital electronic controls achieve high compressor efficiencies with air-cooled water chillers. For the retrofit system having a very constant process cooling charge, the average seasonal NPLV is 49% lower as compared to previous existing conventional air-cooled chillers. The mechanical room noise is also significantly diminished, while the simple pay-back period is estimated at 3.5 years (without subsides) for a technical life of 25 year.
Key concepts: Chiller, Air conditioning, Centrifugal compressor, Gas compressor, Chiller boiler system, Engineering, Condenser (optics), Water cooling