2020Journal of Clinical Laboratory AnalysisOpen access

Performance evaluation of the XPEN60 CRP&SAA, a novel automated hematology analyzer, in detecting complete blood count, C‐reactive protein, and serum amyloid A

Zengyan Zong, Lijuan Kan, Yanping Luo, Cheng Wang, Xibu Wang, Mengmeng Wang, Dan Xiong, Xiuming Zhang

Open full text 4 citations

Abstract

BACKGROUND: The XPEN60 CRP&SAA (hereafter XPEN60) is a new automated hematology analyzer that can rapidly detect C-reactive protein (CRP), serum amyloid A (SAA), and blood cell counts (CBC), including the 5-part differential of white blood cells (5-DIFF). The aim of this study was to evaluate the analytical performance of XPEN60. METHODS: The analytical performance of XPEN60 was evaluated on the basis of several parameters, including the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), precision, accuracy, carryover, linearity, clinical reportable range (CRR), and interference test. In addition, method comparisons between CBC and 5-DIFF, CRP, and SAA were performed on several systems. RESULTS: > .99). LoBs and LoDs (0 and 0.21 mg/L for CRP, 1.1 and 2.27 mg/L for SAA) satisfy the manufacturer's statement. LoQs were 0.61 and 3.62 mg/L for CRP and SAA, respectively. No significant carryover or interference tests (<10%) were observed in this study. The comparison analysis demonstrated strong agreement between XPEN60 results and those of Sysmex-XN1000 (XN1000), except for basophils (Bas) and eosinophils (Eos). The data correlated well with E601 and Mindray CRP-M100 for CRP. CONCLUSION: XPEN60 was demonstrated satisfactory analytical performance, which made it well-suited for use in clinical laboratories, emergency departments, and community hospitals.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The XPEN60 CRP&SAA (hereafter XPEN60) is a new automated hematology analyzer that can rapidly detect C-reactive protein (CRP), serum amyloid A (SAA), and blood cell counts (CBC), including the 5-part differential of white blood cells (5-DIFF). The aim of this study was to evaluate the analytical performance of XPEN60. METHODS: The analytical performance of XPEN60 was evaluated on the basis of several parameters, including the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), precision, accuracy, carryover, linearity, clinical reportable range (CRR), and interference test. In addition, method comparisons between CBC and 5-DIFF, CRP, and SAA were performed on several systems. RESULTS: > .99). LoBs and LoDs (0 and 0.21 mg/L for CRP, 1.1 and 2.27 mg/L for SAA) satisfy the manufacturer's statement. LoQs were 0.61 and 3.62 mg/L for CRP and SAA, respectively. No significant carryover or interference tests (<10%) were observed in this study. The comparison analysis demonstrated strong agreement between XPEN60 results and those of Sysmex-XN1000 (XN1000), except for basophils (Bas) and eosinophils (Eos). The data correlated well with E601 and Mindray CRP-M100 for CRP. CONCLUSION: XPEN60 was demonstrated satisfactory analytical performance, which made it well-suited for use in clinical laboratories, emergency departments, and community hospitals.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The XPEN60 CRP&SAA (hereafter XPEN60) is a new automated hematology analyzer that can rapidly detect C-reactive protein (CRP), serum amyloid A (SAA), and blood cell counts (CBC), including the 5-part differential of white blood cells (5-DIFF). The aim of this study was to evaluate the analytical performance of XPEN60. METHODS: The analytical performance of XPEN60 was evaluated on the basis of several parameters, including the limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ), precision, accuracy, carryover, linearity, clinical reportable range (CRR), and interference test. In addition, method comparisons between CBC and 5-DIFF, CRP, and SAA were performed on several systems. RESULTS: > .99). LoBs and LoDs (0 and 0.21 mg/L for CRP, 1.1 and 2.27 mg/L for SAA) satisfy the manufacturer's statement. LoQs were 0.61 and 3.62 mg/L for CRP and SAA, respectively. No significant carryover or interference tests (<10%) were observed in this study. The comparison analysis demonstrated strong agreement between XPEN60 results and those of Sysmex-XN1000 (XN1000), except for basophils (Bas) and eosinophils (Eos). The data correlated well with E601 and Mindray CRP-M100 for CRP. CONCLUSION: XPEN60 was demonstrated satisfactory analytical performance, which made it well-suited for use in clinical laboratories, emergency departments, and community hospitals.

Key concepts: Hematology analyzer, Serum amyloid A, White blood cell, Detection limit, C-reactive protein, Medicine, Internal medicine, Spectrum analyzer