2011Chinese Journal of Practical OphthalmologyRequires access

Phakic posterior chamber intraocular lens implantation in high myopia with astigmatism

Li Liu, Zi-xin Chen, Mao-sheng Chen, Jin-hua Ma, Rong-pei Chen

Open publisher page 0 citations

Abstract

Objective To valuate the efficacy, safety stability and predictability of implanting a posterior chamber phakic intraocular lens to correct high myopia with astigmatism. Methods Thirty-nine eyes of 22 patients with high myopia were treated with ICL implantation. The range of preop-erative myopia diopters was -7.0 D to -24.0 D, mean -14.50 D±3.50 D, astigmatism ranges -0.50 D to -4.50 D, mean 2.25±1.32 D. All of 39 eyes were implanted ICL successful and had been followed up for 3 to 18 months. The follow up examination included visual acuity, refraction tonometer, slit lamp examination, chamber depth, chamber angle and space between crystal lens and IOL. Results One week after operation, the uncorrected visual acuity of 38 eyes were same or better than the pre-operative best corrected visual acuity (BCVA). The refractive diopters were from -0.50 to -2.25 D,mean -0.75±0.38 D. Astigmatism was 0.25 to 2.75 D, mean 1.03±0.23 D. Complications were seen in 7 eyes of 6 patients who had increased intraocular pressure shortly after surgery (observed in 2hours after operation). After treatment, the intraocular pressure recovered to normal range within 24hours. No complications such as glaucoma, cataract, movement of IOL and retinal detachment occurred in any of the case. Conclusion ICL implantation is administered on the basis of preserving the natural lens. It is predictable, safe and effective in the selected correction methods in high myopia with astigmatism. Key words: High myopia;  Intraocular lens;  Phakic

About this research paper

What this paper is about

Objective To valuate the efficacy, safety stability and predictability of implanting a posterior chamber phakic intraocular lens to correct high myopia with astigmatism. Methods Thirty-nine eyes of 22 patients with high myopia were treated with ICL implantation. The range of preop-erative myopia diopters was -7.0 D to -24.0 D, mean -14.50 D±3.50 D, astigmatism ranges -0.50 D to -4.50 D, mean 2.25±1.32 D. All of 39 eyes were implanted ICL successful and had been followed up for 3 to 18 months. The follow up examination included visual acuity, refraction tonometer, slit lamp examination, chamber depth, chamber angle and space between crystal lens and IOL. Results One week after operation, the uncorrected visual acuity of 38 eyes were same or better than the pre-operative best corrected visual acuity (BCVA). The refractive diopters were from -0.50 to -2.25 D,mean -0.75±0.38 D. Astigmatism was 0.25 to 2.75 D, mean 1.03±0.23 D. Complications were seen in 7 eyes of 6 patients who had increased intraocular pressure shortly after surgery (observed in 2hours after operation). After treatment, the intraocular pressure recovered to normal range within 24hours. No complications such as glaucoma, cataract, movement of IOL and retinal detachment occurred in any of the case. Conclusion ICL implantation is administered on the basis of preserving the natural lens. It is predictable, safe and effective in the selected correction methods in high myopia with astigmatism. Key words: High myopia;  Intraocular lens;  Phakic

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To valuate the efficacy, safety stability and predictability of implanting a posterior chamber phakic intraocular lens to correct high myopia with astigmatism. Methods Thirty-nine eyes of 22 patients with high myopia were treated with ICL implantation. The range of preop-erative myopia diopters was -7.0 D to -24.0 D, mean -14.50 D±3.50 D, astigmatism ranges -0.50 D to -4.50 D, mean 2.25±1.32 D. All of 39 eyes were implanted ICL successful and had been followed up for 3 to 18 months. The follow up examination included visual acuity, refraction tonometer, slit lamp examination, chamber depth, chamber angle and space between crystal lens and IOL. Results One week after operation, the uncorrected visual acuity of 38 eyes were same or better than the pre-operative best corrected visual acuity (BCVA). The refractive diopters were from -0.50 to -2.25 D,mean -0.75±0.38 D. Astigmatism was 0.25 to 2.75 D, mean 1.03±0.23 D. Complications were seen in 7 eyes of 6 patients who had increased intraocular pressure shortly after surgery (observed in 2hours after operation). After treatment, the intraocular pressure recovered to normal range within 24hours. No complications such as glaucoma, cataract, movement of IOL and retinal detachment occurred in any of the case. Conclusion ICL implantation is administered on the basis of preserving the natural lens. It is predictable, safe and effective in the selected correction methods in high myopia with astigmatism. Key words: High myopia;  Intraocular lens;  Phakic

Key concepts: Dioptre, Medicine, Ophthalmology, Astigmatism, Visual acuity, Intraocular pressure, Intraocular lens, Glaucoma

Related papers

Back to paper searchBrowse research topicsOriginal source
Phakic posterior chamber intraocular lens implantation in high myopia with astigmatism — Research Paper | ScholarLens