2011Chinese Journal of Optometry & OphthalmologyRequires access

Use of AcrySof Toric intraocular lenses for correction of residual astigmatism in cataract patients

Qian Xing, Huaijin Guan, Jian Wu, Lili Yuan

Open publisher page 0 citations

Abstract

Objective To evaluate the safety,efficacy,and stability of AcrySof Toric intraocular lens (IOL) implanting in correcting residual astigmatism in patients who have cataract surgery.Methods This was a prospective case control study.Sixty-nine eyes of 59 consecutive cataract patients during a 12-month period who had more than 0.75 diopters (D) of pre-existing astigmatism of the cornea were included.After phacoemulsification,33 patients (37 eyes) were implanted with AcrySof Toric IOL (test group) and 26 patients (32 eyes) with AcrySof SN60AT IOL (control group).One day,1 week,1 month,and 3 months after IOL implantation,uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),residual refractive sphere and cylinder,corneal keratometry,and the AcrySof Toric IOL axis were measured.Visual acuity and residual refractive cylinder distribution were analyzed by Fisher's exact probability and refractions were analyzed by independent samples t tests.Results UCVA:three months after implantation,1 eye (3%) in the test group and 10 eyes (31%) in the control group presented with 0.1-0.3; 22 eyes (60%) in the test group and 15 eyes (47%) in the control group presented with 0.4-0.6; 5 eyes (14%) in the test group and 6 eyes (19%)in the control group presented with 0.7-0.9; and 9 eyes (24%) in the test group and 1 eye (3%) in the control group presented with 1.0 or better.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Residual refractive cylinder:68% of the test group eyes and 12% of the control group eyes had 0-0.75 D; 32% of test group eyes and 59% of the control group eyes had 1-1.75 D; and 0% of the test group eyes and 28% of the control group eyes had more than 2 D.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Rotational stability:3 months after implantation,all AcrySof Toric IOL had rotated less than 20 degrees:IOL in 21 eyes (57%) had rotated less than 5 degrees,IOL in 7 eyes (19%) had rotated 6°-10°,and IOL in 9 eyes (24%) had rotated 11°-15°.The mean AcrySof Toric IOL axis rotation was 5.8°±5.0° (0°-15°).Surgically induced astigmatism (SIA):the mean SIA was (0.66±0.17)D in the test group and (0.62±0.24)D in the control group.There was no statistically significant differences between the two groups.Conclusion The results show that phacoemuisification and AcrySof Toric IOL implantation are safe and effective to correct residual astigmatism 3 months after cataract surgery. Key words: Lenses,intraocular,astigmatism;  Astigmatism;  Phacoemulsification

About this research paper

What this paper is about

Objective To evaluate the safety,efficacy,and stability of AcrySof Toric intraocular lens (IOL) implanting in correcting residual astigmatism in patients who have cataract surgery.Methods This was a prospective case control study.Sixty-nine eyes of 59 consecutive cataract patients during a 12-month period who had more than 0.75 diopters (D) of pre-existing astigmatism of the cornea were included.After phacoemulsification,33 patients (37 eyes) were implanted with AcrySof Toric IOL (test group) and 26 patients (32 eyes) with AcrySof SN60AT IOL (control group).One day,1 week,1 month,and 3 months after IOL implantation,uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),residual refractive sphere and cylinder,corneal keratometry,and the AcrySof Toric IOL axis were measured.Visual acuity and residual refractive cylinder distribution were analyzed by Fisher's exact probability and refractions were analyzed by independent samples t tests.Results UCVA:three months after implantation,1 eye (3%) in the test group and 10 eyes (31%) in the control group presented with 0.1-0.3; 22 eyes (60%) in the test group and 15 eyes (47%) in the control group presented with 0.4-0.6; 5 eyes (14%) in the test group and 6 eyes (19%)in the control group presented with 0.7-0.9; and 9 eyes (24%) in the test group and 1 eye (3%) in the control group presented with 1.0 or better.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Residual refractive cylinder:68% of the test group eyes and 12% of the control group eyes had 0-0.75 D; 32% of test group eyes and 59% of the control group eyes had 1-1.75 D; and 0% of the test group eyes and 28% of the control group eyes had more than 2 D.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Rotational stability:3 months after implantation,all AcrySof Toric IOL had rotated less than 20 degrees:IOL in 21 eyes (57%) had rotated less than 5 degrees,IOL in 7 eyes (19%) had rotated 6°-10°,and IOL in 9 eyes (24%) had rotated 11°-15°.The mean AcrySof Toric IOL axis rotation was 5.8°±5.0° (0°-15°).Surgically induced astigmatism (SIA):the mean SIA was (0.66±0.17)D in the test group and (0.62±0.24)D in the control group.There was no statistically significant differences between the two groups.Conclusion The results show that phacoemuisification and AcrySof Toric IOL implantation are safe and effective to correct residual astigmatism 3 months after cataract surgery. Key words: Lenses,intraocular,astigmatism;  Astigmatism;  Phacoemulsification

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the safety,efficacy,and stability of AcrySof Toric intraocular lens (IOL) implanting in correcting residual astigmatism in patients who have cataract surgery.Methods This was a prospective case control study.Sixty-nine eyes of 59 consecutive cataract patients during a 12-month period who had more than 0.75 diopters (D) of pre-existing astigmatism of the cornea were included.After phacoemulsification,33 patients (37 eyes) were implanted with AcrySof Toric IOL (test group) and 26 patients (32 eyes) with AcrySof SN60AT IOL (control group).One day,1 week,1 month,and 3 months after IOL implantation,uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),residual refractive sphere and cylinder,corneal keratometry,and the AcrySof Toric IOL axis were measured.Visual acuity and residual refractive cylinder distribution were analyzed by Fisher's exact probability and refractions were analyzed by independent samples t tests.Results UCVA:three months after implantation,1 eye (3%) in the test group and 10 eyes (31%) in the control group presented with 0.1-0.3; 22 eyes (60%) in the test group and 15 eyes (47%) in the control group presented with 0.4-0.6; 5 eyes (14%) in the test group and 6 eyes (19%)in the control group presented with 0.7-0.9; and 9 eyes (24%) in the test group and 1 eye (3%) in the control group presented with 1.0 or better.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Residual refractive cylinder:68% of the test group eyes and 12% of the control group eyes had 0-0.75 D; 32% of test group eyes and 59% of the control group eyes had 1-1.75 D; and 0% of the test group eyes and 28% of the control group eyes had more than 2 D.There were statistically significant differences between the two groups (Fisher's exact=0.000,P<0.05).Rotational stability:3 months after implantation,all AcrySof Toric IOL had rotated less than 20 degrees:IOL in 21 eyes (57%) had rotated less than 5 degrees,IOL in 7 eyes (19%) had rotated 6°-10°,and IOL in 9 eyes (24%) had rotated 11°-15°.The mean AcrySof Toric IOL axis rotation was 5.8°±5.0° (0°-15°).Surgically induced astigmatism (SIA):the mean SIA was (0.66±0.17)D in the test group and (0.62±0.24)D in the control group.There was no statistically significant differences between the two groups.Conclusion The results show that phacoemuisification and AcrySof Toric IOL implantation are safe and effective to correct residual astigmatism 3 months after cataract surgery. Key words: Lenses,intraocular,astigmatism;  Astigmatism;  Phacoemulsification

Key concepts: Medicine, Ophthalmology, Intraocular lens, Dioptre, Astigmatism, Keratometer, Phacoemulsification, Visual acuity

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of AcrySof Toric intraocular lenses for correction of residual astigmatism in cataract patients — Research Paper | ScholarLens