2016Nigerian Journal of OphthalmologyOpen access

Visual outcomes after phacoemulsification with AcrySof toric intraocular lens implantation

Jaya Kaushik, Vaibhav K Jain, Jitendra Kumar Singh Parihar, Piyush Chaturvedi, Vijay Mathur, SanjayK Dhar

Open full text 0 citations

Abstract

Introduction: To study the visual outcome of AcrySof toric intraocular lens (IOL) implantation in patients having cataract associated with astigmatism. Materials and Methods: In this prospective interventional case series, 30 eyes of 28 patients with preoperative astigmatism of 1.5–4.5 D cylinder underwent phacoemulsification with AcrySof toric IOL implantation. All patients were assessed on day 1, 1 week, 1 month, 2 months, and 3 months postoperatively. The outcome measures were uncorrected visual acuity (UCVA), refractive cylinder, and degree of IOL rotation. Results: Mean UCVA improved significantly in study eyes (P < 0.05) at 3 months. The mean refractive astigmatism reduced from the preoperative value 3.05 ± 0.06 D to 0.208 ± 0.058 D (P = 0.001). The mean axis of rotation was 2.76 ± 1.88° in all eyes. Ninety percent of all eyes had mean axis of IOL rotation 10°. Only three eyes had mean axis of rotation 10° or more. Conclusion: AcrySof toric IOL implantation is an effective method to correct preoperative astigmatism in cataract patients.

About this research paper

What this paper is about

Introduction: To study the visual outcome of AcrySof toric intraocular lens (IOL) implantation in patients having cataract associated with astigmatism. Materials and Methods: In this prospective interventional case series, 30 eyes of 28 patients with preoperative astigmatism of 1.5–4.5 D cylinder underwent phacoemulsification with AcrySof toric IOL implantation. All patients were assessed on day 1, 1 week, 1 month, 2 months, and 3 months postoperatively. The outcome measures were uncorrected visual acuity (UCVA), refractive cylinder, and degree of IOL rotation. Results: Mean UCVA improved significantly in study eyes (P < 0.05) at 3 months. The mean refractive astigmatism reduced from the preoperative value 3.05 ± 0.06 D to 0.208 ± 0.058 D (P = 0.001). The mean axis of rotation was 2.76 ± 1.88° in all eyes. Ninety percent of all eyes had mean axis of IOL rotation 10°. Only three eyes had mean axis of rotation 10° or more. Conclusion: AcrySof toric IOL implantation is an effective method to correct preoperative astigmatism in cataract patients.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: To study the visual outcome of AcrySof toric intraocular lens (IOL) implantation in patients having cataract associated with astigmatism. Materials and Methods: In this prospective interventional case series, 30 eyes of 28 patients with preoperative astigmatism of 1.5–4.5 D cylinder underwent phacoemulsification with AcrySof toric IOL implantation. All patients were assessed on day 1, 1 week, 1 month, 2 months, and 3 months postoperatively. The outcome measures were uncorrected visual acuity (UCVA), refractive cylinder, and degree of IOL rotation. Results: Mean UCVA improved significantly in study eyes (P < 0.05) at 3 months. The mean refractive astigmatism reduced from the preoperative value 3.05 ± 0.06 D to 0.208 ± 0.058 D (P = 0.001). The mean axis of rotation was 2.76 ± 1.88° in all eyes. Ninety percent of all eyes had mean axis of IOL rotation 10°. Only three eyes had mean axis of rotation 10° or more. Conclusion: AcrySof toric IOL implantation is an effective method to correct preoperative astigmatism in cataract patients.

Key concepts: Medicine, Phacoemulsification, Astigmatism, Intraocular lens, Ophthalmology, Intraocular lenses, Visual acuity, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Visual outcomes after phacoemulsification with AcrySof toric intraocular lens implantation — Research Paper | ScholarLens