2012Chinese Journal of Optometry & OphthalmologyRequires access

Comparison of different optometric tests to measure refraction before LASIK

Xiaoxiao Zhang, Zheng Wang, Hua Zheng

Open publisher page 0 citations

Abstract

Objective To compare the accuracy and reliability of refraction with different optometric tests before laser in situ keratomileusis (LASIK).Methods It was a prospective clinical study.Two hundred and forty one eyes of 122 myopes with a spherical range of-0.75~-13.25 D,average,-5.57±2.40 D and cylinder range of-0.25~-5.50 D,average,-0.96-±0.66 D.Four different optometric tests were used before the excimer laser surgery: cycloplegic retinoscopy,autorefraction,subjective refraction and Orbscan Ⅱ.Subjective refraction was performed on the patients 1 year postoperatively.Data were analyzed using one-way ANOVA,a paired samples t test and Pearson correlation.Results The mean spherical results with cycloplegic retinoscopy,autorefraction and subjective refraction were-5.20±2.61 D,-5.64±2.71 D and-5.57±2.40 D,respectively.These were significantly different (F=38.586,P<0.01).The mean cylinder results with cycloplegic retinoscopy,autorefraction and subjective refraction were-0.99±0.66 D,-1.03±0.73 D and-0.96±0.66 D.These were significantly different (F=15.147,P<0.01).The cylinder measured by Orbscan Ⅱ was-1.16±1.84 D,which was significantly different from the result by subjective refraction (t=3.190,P<0.01).A Pearson correlation showed a high correlation for the results from the different optometric tests (r>0.9 for all,P<0.01 for all).Conclusion It is important to note in clinical practice,comprehensive optometric tests are necessary for the success of excimer laser surgery. Key words: Excimer laser surgery ;  Cycloplegic retinoscopy ;  Autorefraction ;  Subjective refraction ;  Orbscan Ⅱ

About this research paper

What this paper is about

Objective To compare the accuracy and reliability of refraction with different optometric tests before laser in situ keratomileusis (LASIK).Methods It was a prospective clinical study.Two hundred and forty one eyes of 122 myopes with a spherical range of-0.75~-13.25 D,average,-5.57±2.40 D and cylinder range of-0.25~-5.50 D,average,-0.96-±0.66 D.Four different optometric tests were used before the excimer laser surgery: cycloplegic retinoscopy,autorefraction,subjective refraction and Orbscan Ⅱ.Subjective refraction was performed on the patients 1 year postoperatively.Data were analyzed using one-way ANOVA,a paired samples t test and Pearson correlation.Results The mean spherical results with cycloplegic retinoscopy,autorefraction and subjective refraction were-5.20±2.61 D,-5.64±2.71 D and-5.57±2.40 D,respectively.These were significantly different (F=38.586,P<0.01).The mean cylinder results with cycloplegic retinoscopy,autorefraction and subjective refraction were-0.99±0.66 D,-1.03±0.73 D and-0.96±0.66 D.These were significantly different (F=15.147,P<0.01).The cylinder measured by Orbscan Ⅱ was-1.16±1.84 D,which was significantly different from the result by subjective refraction (t=3.190,P<0.01).A Pearson correlation showed a high correlation for the results from the different optometric tests (r>0.9 for all,P<0.01 for all).Conclusion It is important to note in clinical practice,comprehensive optometric tests are necessary for the success of excimer laser surgery. Key words: Excimer laser surgery ;  Cycloplegic retinoscopy ;  Autorefraction ;  Subjective refraction ;  Orbscan Ⅱ

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare the accuracy and reliability of refraction with different optometric tests before laser in situ keratomileusis (LASIK).Methods It was a prospective clinical study.Two hundred and forty one eyes of 122 myopes with a spherical range of-0.75~-13.25 D,average,-5.57±2.40 D and cylinder range of-0.25~-5.50 D,average,-0.96-±0.66 D.Four different optometric tests were used before the excimer laser surgery: cycloplegic retinoscopy,autorefraction,subjective refraction and Orbscan Ⅱ.Subjective refraction was performed on the patients 1 year postoperatively.Data were analyzed using one-way ANOVA,a paired samples t test and Pearson correlation.Results The mean spherical results with cycloplegic retinoscopy,autorefraction and subjective refraction were-5.20±2.61 D,-5.64±2.71 D and-5.57±2.40 D,respectively.These were significantly different (F=38.586,P<0.01).The mean cylinder results with cycloplegic retinoscopy,autorefraction and subjective refraction were-0.99±0.66 D,-1.03±0.73 D and-0.96±0.66 D.These were significantly different (F=15.147,P<0.01).The cylinder measured by Orbscan Ⅱ was-1.16±1.84 D,which was significantly different from the result by subjective refraction (t=3.190,P<0.01).A Pearson correlation showed a high correlation for the results from the different optometric tests (r>0.9 for all,P<0.01 for all).Conclusion It is important to note in clinical practice,comprehensive optometric tests are necessary for the success of excimer laser surgery. Key words: Excimer laser surgery ;  Cycloplegic retinoscopy ;  Autorefraction ;  Subjective refraction ;  Orbscan Ⅱ

Key concepts: Retinoscopy, LASIK, Subjective refraction, Keratomileusis, Medicine, Ophthalmology, Optometry, Refraction

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of different optometric tests to measure refraction before LASIK — Research Paper | ScholarLens