Retinoscopy/autorefraction: which is the best starting point for a noncycloplegic refraction?

Jorge Jorge, António Queirós, José B. Almeida, Manuel Ángel Parafita

Open full text 76 citations

Abstract

PURPOSE: The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A, Gamagori, Japan) and retinoscopy with subjective refraction. METHODS: Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements were performed without cycloplegia. The age range was 18 to 34 years, with a mean value of 21.6 years and an SD of 2.66 years. RESULTS: A comparison of the autorefractor and subjective refraction results shows that (1) for the mean spherical equivalent (M), the autorefractor yields more negative values (-0.44 +/- 0.54 D; p = 0.000); (2) for the Jackson cross-cylinder at axis 0 degrees (J0), the autorefractor yields more positive values than the subjective ones (0.05 +/- 0.13 D; p = 0.000); and (3) for the Jackson cross-cylinder at axis 45 degrees (J45), the autorefractor results are more negative (-0.02 +/- 0.09 D; p = 0.019). The differences found for each component M, J0, and J45 are statistically significant. By comparing retinoscopy with the subjective examination, there are no statistically significant differences found for the M component (-0.02 +/- 0.33 D; p = 0.304). For the J0 and J45 components, the differences are statistically significant (0.07 +/- 0.10 D, p = 0.000; -0.01 +/- 0.08 D, p = 0.008). CONCLUSIONS: The present results confirm that when performed by an experienced clinician, retinoscopy is more accurate than automatic refraction, giving a better starting point to noncycloplegic refraction.

Open-access reader

About this research paper

What this paper is about

PURPOSE: The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A, Gamagori, Japan) and retinoscopy with subjective refraction. METHODS: Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements were performed without cycloplegia. The age range was 18 to 34 years, with a mean value of 21.6 years and an SD of 2.66 years. RESULTS: A comparison of the autorefractor and subjective refraction results shows that (1) for the mean spherical equivalent (M), the autorefractor yields more negative values (-0.44 +/- 0.54 D; p = 0.000); (2) for the Jackson cross-cylinder at axis 0 degrees (J0), the autorefractor yields more positive values than the subjective ones (0.05 +/- 0.13 D; p = 0.000); and (3) for the Jackson cross-cylinder at axis 45 degrees (J45), the autorefractor results are more negative (-0.02 +/- 0.09 D; p = 0.019). The differences found for each component M, J0, and J45 are statistically significant. By comparing retinoscopy with the subjective examination, there are no statistically significant differences found for the M component (-0.02 +/- 0.33 D; p = 0.304). For the J0 and J45 components, the differences are statistically significant (0.07 +/- 0.10 D, p = 0.000; -0.01 +/- 0.08 D, p = 0.008). CONCLUSIONS: The present results confirm that when performed by an experienced clinician, retinoscopy is more accurate than automatic refraction, giving a better starting point to noncycloplegic refraction.

Why it matters

OpenAlex reports 76 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A, Gamagori, Japan) and retinoscopy with subjective refraction. METHODS: Measurements of autorefraction obtained with the ARK700A and retinoscopy were performed on 192 right eyes from 192 healthy young adults and compared with subjective refraction. These measurements were performed without cycloplegia. The age range was 18 to 34 years, with a mean value of 21.6 years and an SD of 2.66 years. RESULTS: A comparison of the autorefractor and subjective refraction results shows that (1) for the mean spherical equivalent (M), the autorefractor yields more negative values (-0.44 +/- 0.54 D; p = 0.000); (2) for the Jackson cross-cylinder at axis 0 degrees (J0), the autorefractor yields more positive values than the subjective ones (0.05 +/- 0.13 D; p = 0.000); and (3) for the Jackson cross-cylinder at axis 45 degrees (J45), the autorefractor results are more negative (-0.02 +/- 0.09 D; p = 0.019). The differences found for each component M, J0, and J45 are statistically significant. By comparing retinoscopy with the subjective examination, there are no statistically significant differences found for the M component (-0.02 +/- 0.33 D; p = 0.304). For the J0 and J45 components, the differences are statistically significant (0.07 +/- 0.10 D, p = 0.000; -0.01 +/- 0.08 D, p = 0.008). CONCLUSIONS: The present results confirm that when performed by an experienced clinician, retinoscopy is more accurate than automatic refraction, giving a better starting point to noncycloplegic refraction.

Key concepts: Autorefractor, Retinoscopy, Cycloplegia, Subjective refraction, Optometry, Mathematics, Refraction, Limits of agreement