2017Chinese Journal of Practical OphthalmologyRequires access

The effects of refractive status and central corneal thickness on applanation tonometry measurements

Ning Li, Qian Zhong

Open publisher page 0 citations

Abstract

Objective To investigate the effect of the refractive status and central cornea thickness (CCT) on Goldmann applanation tonometry (GAT). Methods A total of 119 cases of normal subjects (195 eyes) and 74 cases of myopia (148 eyes) were included in this study. The CCT was measured by Pentacam and intraocular pressure (IOP) by using GAT. SPSS17.0 was used to process the data. Results The average CCT of the normal group was (525.07±38.58)μm. The mean IOP was (12.96±2.64)mmHg. The difference on both IOP and the mean CCT between low myopia group and normal group had statistically significant. The difference in IOP between high myopia group and normal group had statistically significant. The IOP of myopia group was negatively correlated with diopter (r=-0.396, P <0.001). IOP increased 1mmHg with per -3.86D increase. IOP of normal and myopic groups correction formulas were 1mmHg/45.55μm, 1mmHg/34.46μm, respectively. Conclusions CCT and refractive state can influence IOP. Key words: Refractive status; Central corneal thickness; Goldmann applanation tonometry; Pentacam; IOP correction

About this research paper

What this paper is about

Objective To investigate the effect of the refractive status and central cornea thickness (CCT) on Goldmann applanation tonometry (GAT). Methods A total of 119 cases of normal subjects (195 eyes) and 74 cases of myopia (148 eyes) were included in this study. The CCT was measured by Pentacam and intraocular pressure (IOP) by using GAT. SPSS17.0 was used to process the data. Results The average CCT of the normal group was (525.07±38.58)μm. The mean IOP was (12.96±2.64)mmHg. The difference on both IOP and the mean CCT between low myopia group and normal group had statistically significant. The difference in IOP between high myopia group and normal group had statistically significant. The IOP of myopia group was negatively correlated with diopter (r=-0.396, P <0.001). IOP increased 1mmHg with per -3.86D increase. IOP of normal and myopic groups correction formulas were 1mmHg/45.55μm, 1mmHg/34.46μm, respectively. Conclusions CCT and refractive state can influence IOP. Key words: Refractive status; Central corneal thickness; Goldmann applanation tonometry; Pentacam; IOP correction

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the effect of the refractive status and central cornea thickness (CCT) on Goldmann applanation tonometry (GAT). Methods A total of 119 cases of normal subjects (195 eyes) and 74 cases of myopia (148 eyes) were included in this study. The CCT was measured by Pentacam and intraocular pressure (IOP) by using GAT. SPSS17.0 was used to process the data. Results The average CCT of the normal group was (525.07±38.58)μm. The mean IOP was (12.96±2.64)mmHg. The difference on both IOP and the mean CCT between low myopia group and normal group had statistically significant. The difference in IOP between high myopia group and normal group had statistically significant. The IOP of myopia group was negatively correlated with diopter (r=-0.396, P <0.001). IOP increased 1mmHg with per -3.86D increase. IOP of normal and myopic groups correction formulas were 1mmHg/45.55μm, 1mmHg/34.46μm, respectively. Conclusions CCT and refractive state can influence IOP. Key words: Refractive status; Central corneal thickness; Goldmann applanation tonometry; Pentacam; IOP correction

Key concepts: Medicine, Dioptre, Ophthalmology, Intraocular pressure, Cornea, Goldmann Applanation Tonometer, Applanation tonometry, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
The effects of refractive status and central corneal thickness on applanation tonometry measurements — Research Paper | ScholarLens