Clinical reports about Chinese-made silicone intraocular lens implantation and small-incision pha- coemulsification cataract surgery
沈志兵
Abstract
沈志兵
Abstract
Objective To investigate the clinical results of the non-phacoemulsification small incision cataract extraction and silicone intraocular lens implantation, compared to the effect of Chinese-made silicone intraocular lens and imported silicone intraocular lens. Methods Ninety-eight cases (103 eyes) were randomly divided into the small-incision after phacoemulsification and implanted intraocular lens of the domestical Exlen group and imported Cannon Starr group. Vision, anterior chamber inflammation and other complications were observed and recorded 1 day, 1 week, 1 month and 6 months after surgery. Results The best corrected visual acuity ≥ 1.0 in 24 eyes (23.53%), best corrected visual acuity ≥0.5 (70.59%), no serious complications occurred.Conclusions The efficacy ofsmall incision phacoemulsification cataract extraction and intraocular lens implantation between domestically produced Exlen and imported Cannon Starr silicone intraocular lens is similar. Key words: Cataract; Small incision; Intraocular lens; Artificial; Silicon
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To investigate the clinical results of the non-phacoemulsification small incision cataract extraction and silicone intraocular lens implantation, compared to the effect of Chinese-made silicone intraocular lens and imported silicone intraocular lens. Methods Ninety-eight cases (103 eyes) were randomly divided into the small-incision after phacoemulsification and implanted intraocular lens of the domestical Exlen group and imported Cannon Starr group. Vision, anterior chamber inflammation and other complications were observed and recorded 1 day, 1 week, 1 month and 6 months after surgery. Results The best corrected visual acuity ≥ 1.0 in 24 eyes (23.53%), best corrected visual acuity ≥0.5 (70.59%), no serious complications occurred.Conclusions The efficacy ofsmall incision phacoemulsification cataract extraction and intraocular lens implantation between domestically produced Exlen and imported Cannon Starr silicone intraocular lens is similar. Key words: Cataract; Small incision; Intraocular lens; Artificial; Silicon
Key concepts: Phacoemulsification, Medicine, Intraocular lens, Ophthalmology, Visual acuity, Silicone, Lens (geology), Cataract surgery