2012Zhonghua xiandai huli zazhiRequires access

Effect of two radial artery puncture methods on the neonatal blood collection

王文珍, 支晨

Open publisher page 0 citations

Abstract

Objective To explore touch puncture method and wired positioning puncture method on the neonatal blood collection via radial artery.Methods Totals of 600 newborns needed blood collection via radial artery were randomly into experimental group and control group,per group 300 cases.Control group received traditional touch method to puncture,while experimental group on the bases of puncture method received anatomy wired positioning puncture.Then,the success ratio of one-time puncture,puncture time and complications were compared.Results The success ratio of one-time puncture of experimental group was 96.0% higher than control group that was 88.3%,and the difference was statistically significant( x2 =12.21,P<0.01) ;Puncture time of experimental group was(2.82 ±0.24) min lower than control group that was (3.93 ± 0.50) min,and the difference was statistically significant ( t =9.897,P < 0.01 ) ; The incidence of complications of experimental group was 3.3% lower than control group that was 7.6%,and the difference was statistically significant (x2 =5.44,P < 0.05 ).Conclusions Anatomy wired positioning method using in neonatal blood collection has a strong operability and high puncture success ratio,which deserves to be spread and used in the clinic. Key words: Infant,newborn;  Radial artery;  Puncture

About this research paper

What this paper is about

Objective To explore touch puncture method and wired positioning puncture method on the neonatal blood collection via radial artery.Methods Totals of 600 newborns needed blood collection via radial artery were randomly into experimental group and control group,per group 300 cases.Control group received traditional touch method to puncture,while experimental group on the bases of puncture method received anatomy wired positioning puncture.Then,the success ratio of one-time puncture,puncture time and complications were compared.Results The success ratio of one-time puncture of experimental group was 96.0% higher than control group that was 88.3%,and the difference was statistically significant( x2 =12.21,P<0.01) ;Puncture time of experimental group was(2.82 ±0.24) min lower than control group that was (3.93 ± 0.50) min,and the difference was statistically significant ( t =9.897,P < 0.01 ) ; The incidence of complications of experimental group was 3.3% lower than control group that was 7.6%,and the difference was statistically significant (x2 =5.44,P < 0.05 ).Conclusions Anatomy wired positioning method using in neonatal blood collection has a strong operability and high puncture success ratio,which deserves to be spread and used in the clinic. Key words: Infant,newborn;  Radial artery;  Puncture

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore touch puncture method and wired positioning puncture method on the neonatal blood collection via radial artery.Methods Totals of 600 newborns needed blood collection via radial artery were randomly into experimental group and control group,per group 300 cases.Control group received traditional touch method to puncture,while experimental group on the bases of puncture method received anatomy wired positioning puncture.Then,the success ratio of one-time puncture,puncture time and complications were compared.Results The success ratio of one-time puncture of experimental group was 96.0% higher than control group that was 88.3%,and the difference was statistically significant( x2 =12.21,P<0.01) ;Puncture time of experimental group was(2.82 ±0.24) min lower than control group that was (3.93 ± 0.50) min,and the difference was statistically significant ( t =9.897,P < 0.01 ) ; The incidence of complications of experimental group was 3.3% lower than control group that was 7.6%,and the difference was statistically significant (x2 =5.44,P < 0.05 ).Conclusions Anatomy wired positioning method using in neonatal blood collection has a strong operability and high puncture success ratio,which deserves to be spread and used in the clinic. Key words: Infant,newborn;  Radial artery;  Puncture

Key concepts: Medicine, Blood collection, Significant difference, Radial artery, Surgery, Anesthesia, Artery, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of two radial artery puncture methods on the neonatal blood collection — Research Paper | ScholarLens