2011Zhongguo jiceng yiyaoRequires access

Clinical application of the modified Epworth Sleepiness Score in the gestation women combined with obstructive sleep apnea-hypopnea syndrome

Zhong Xu, Qiao-li Luo, Huishu Liu, Dongjian Huang, Dunjin Chen

Open publisher page 0 citations

Abstract

Objective Screening OSAHS patients on pregnancy with Modified Epworth Sleepiness Scale( Epworth sleepiness scale,ESS)and to assess its effect. Methods 22 patients underwent the pregnancy,and pregnancy with OSAHS( mild in 23 cases,22 cases of moderate and severe in 19 cases)group were 64 people, By ESS and modified ESS score, EP and modified EP values was derived. The neck circumference ( NC), body mass index (BMI) was measured. Conduct of polysomnography ( PSG), apnea hypopnea index ( AHI ) and lowest oxygen saturation ( LSaO2 )ESS and modified ESS correlation with the AHI was analyzed and ROC curves was drawn. Results The EP value of pregnancy with mild OSAHS group has no significant difference between normal pregnancy group( P > 0.05) ;the rest of pregnancy OSAHS group modified EP, EP values and the normal pregnancy group were significantly different ( all P<0.05) ;modified EP, EP, NC, BMI values positively correlated with the AHI value, the correlation coefficient r were :0.876,0.748,0.671,0.670 ( all P < 0.001 ) ;modified EP, EP, NC, BM I of the A UC values were 0.901,0.819,0.750, 0.779; when the modified EP = 8.5, had higher sensitivity ( 84.4% ) and specificity ( 90.9% ).Conclusion Modified ESS on pregnancy OSAHS patients had better clinical value of screening. Key words: Sleep apnea-hypopnea syndrome; Pregnancy; Epworth sleepiness score; Screening; Neck circumference; Body mass index

About this research paper

What this paper is about

Objective Screening OSAHS patients on pregnancy with Modified Epworth Sleepiness Scale( Epworth sleepiness scale,ESS)and to assess its effect. Methods 22 patients underwent the pregnancy,and pregnancy with OSAHS( mild in 23 cases,22 cases of moderate and severe in 19 cases)group were 64 people, By ESS and modified ESS score, EP and modified EP values was derived. The neck circumference ( NC), body mass index (BMI) was measured. Conduct of polysomnography ( PSG), apnea hypopnea index ( AHI ) and lowest oxygen saturation ( LSaO2 )ESS and modified ESS correlation with the AHI was analyzed and ROC curves was drawn. Results The EP value of pregnancy with mild OSAHS group has no significant difference between normal pregnancy group( P > 0.05) ;the rest of pregnancy OSAHS group modified EP, EP values and the normal pregnancy group were significantly different ( all P<0.05) ;modified EP, EP, NC, BMI values positively correlated with the AHI value, the correlation coefficient r were :0.876,0.748,0.671,0.670 ( all P < 0.001 ) ;modified EP, EP, NC, BM I of the A UC values were 0.901,0.819,0.750, 0.779; when the modified EP = 8.5, had higher sensitivity ( 84.4% ) and specificity ( 90.9% ).Conclusion Modified ESS on pregnancy OSAHS patients had better clinical value of screening. Key words: Sleep apnea-hypopnea syndrome; Pregnancy; Epworth sleepiness score; Screening; Neck circumference; Body mass index

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective Screening OSAHS patients on pregnancy with Modified Epworth Sleepiness Scale( Epworth sleepiness scale,ESS)and to assess its effect. Methods 22 patients underwent the pregnancy,and pregnancy with OSAHS( mild in 23 cases,22 cases of moderate and severe in 19 cases)group were 64 people, By ESS and modified ESS score, EP and modified EP values was derived. The neck circumference ( NC), body mass index (BMI) was measured. Conduct of polysomnography ( PSG), apnea hypopnea index ( AHI ) and lowest oxygen saturation ( LSaO2 )ESS and modified ESS correlation with the AHI was analyzed and ROC curves was drawn. Results The EP value of pregnancy with mild OSAHS group has no significant difference between normal pregnancy group( P > 0.05) ;the rest of pregnancy OSAHS group modified EP, EP values and the normal pregnancy group were significantly different ( all P<0.05) ;modified EP, EP, NC, BMI values positively correlated with the AHI value, the correlation coefficient r were :0.876,0.748,0.671,0.670 ( all P < 0.001 ) ;modified EP, EP, NC, BM I of the A UC values were 0.901,0.819,0.750, 0.779; when the modified EP = 8.5, had higher sensitivity ( 84.4% ) and specificity ( 90.9% ).Conclusion Modified ESS on pregnancy OSAHS patients had better clinical value of screening. Key words: Sleep apnea-hypopnea syndrome; Pregnancy; Epworth sleepiness score; Screening; Neck circumference; Body mass index

Key concepts: Epworth Sleepiness Scale, Medicine, Hypopnea, Polysomnography, Body mass index, Pregnancy, Obstructive sleep apnea, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical application of the modified Epworth Sleepiness Score in the gestation women combined with obstructive sleep apnea-hypopnea syndrome — Research Paper | ScholarLens