2013Guoji mazuixue yu fusu zazhiRequires access

Application of self-made microphone light wand in patients with difficult airway

Shao-duan Ni, Cong-xue Ma

Open publisher page 0 citations

Abstract

Objective To study the clinical efficacy of self-made microphone light wand in patients with difficult airway.Methods 42 patients with difficult airway scheduled for tracheal intubation were randomly divided into two groups,21 cases in each group.Self-made microphone light wand was used in group Ⅰ,while laryngoscope was used in group lⅡ.The first successful rate of intubation and the time of intubation were recorded.Hemodynamic change and the complications of intubation were observed in all patients.Results There were no difference in age,sex and weight between two groups (P>0.05).The first successful rate of intubation in group Ⅰ was significantly higher than that in group Ⅱ (90.5% vs 57.1%,P<0.05),the time of intubation decreased significantly in group Ⅰ [(86±19) s vs (276±36) s,P<0.05].Compared with group lⅡ,the complications of intubation such as hemodynamic change,oropharyngeal mucosal hemorrhage,sore throat and hoarseness in group Ⅰ were better(P<0.05).Conclusions Self-made microphone light wand is relatively safe,effective and promising in patients with difficult airway. Key words: Self-made microphone light wand;  Difficult airway;  Tracheal intubation

About this research paper

What this paper is about

Objective To study the clinical efficacy of self-made microphone light wand in patients with difficult airway.Methods 42 patients with difficult airway scheduled for tracheal intubation were randomly divided into two groups,21 cases in each group.Self-made microphone light wand was used in group Ⅰ,while laryngoscope was used in group lⅡ.The first successful rate of intubation and the time of intubation were recorded.Hemodynamic change and the complications of intubation were observed in all patients.Results There were no difference in age,sex and weight between two groups (P>0.05).The first successful rate of intubation in group Ⅰ was significantly higher than that in group Ⅱ (90.5% vs 57.1%,P<0.05),the time of intubation decreased significantly in group Ⅰ [(86±19) s vs (276±36) s,P<0.05].Compared with group lⅡ,the complications of intubation such as hemodynamic change,oropharyngeal mucosal hemorrhage,sore throat and hoarseness in group Ⅰ were better(P<0.05).Conclusions Self-made microphone light wand is relatively safe,effective and promising in patients with difficult airway. Key words: Self-made microphone light wand;  Difficult airway;  Tracheal intubation

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To study the clinical efficacy of self-made microphone light wand in patients with difficult airway.Methods 42 patients with difficult airway scheduled for tracheal intubation were randomly divided into two groups,21 cases in each group.Self-made microphone light wand was used in group Ⅰ,while laryngoscope was used in group lⅡ.The first successful rate of intubation and the time of intubation were recorded.Hemodynamic change and the complications of intubation were observed in all patients.Results There were no difference in age,sex and weight between two groups (P>0.05).The first successful rate of intubation in group Ⅰ was significantly higher than that in group Ⅱ (90.5% vs 57.1%,P<0.05),the time of intubation decreased significantly in group Ⅰ [(86±19) s vs (276±36) s,P<0.05].Compared with group lⅡ,the complications of intubation such as hemodynamic change,oropharyngeal mucosal hemorrhage,sore throat and hoarseness in group Ⅰ were better(P<0.05).Conclusions Self-made microphone light wand is relatively safe,effective and promising in patients with difficult airway. Key words: Self-made microphone light wand;  Difficult airway;  Tracheal intubation

Key concepts: Sore throat, Intubation, Medicine, Airway, Anesthesia, Tracheal intubation, Throat, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of self-made microphone light wand in patients with difficult airway — Research Paper | ScholarLens