Objective To compare the effects of artificial nose and electric heating thermostat humidification jar on preventing ventilator-associated pneumonia of severe mechanical ventilation .Methods One hundred and eighty patients who respectively used the artificial nose ( the experimental group ) and electric heating thermostat humidification jar ( the control group ) were matched according to the age and sex , each with 90 cases.The effect of humidification, the incidence rate of ventilator-associated pneumonia (VAP) and the mortality rate were compared between the two groups .Results The cases of Grade Ⅲ sticky sputum were 19 cases in the experimental group , and were 34 cases in the control group , and the difference was statistically significant (χ2 =6.83, P 0.05).Conclusions The artificial nose can reduce the incidence rate of VAP , and decrease the nursing workload and the burden of patients to a certain extent . Key words: Artificial nose; Electric heating thermostat humidification jar; Pneumonia,ventilator-associated
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To compare the effects of artificial nose and electric heating thermostat humidification jar on preventing ventilator-associated pneumonia of severe mechanical ventilation .Methods One hundred and eighty patients who respectively used the artificial nose ( the experimental group ) and electric heating thermostat humidification jar ( the control group ) were matched according to the age and sex , each with 90 cases.The effect of humidification, the incidence rate of ventilator-associated pneumonia (VAP) and the mortality rate were compared between the two groups .Results The cases of Grade Ⅲ sticky sputum were 19 cases in the experimental group , and were 34 cases in the control group , and the difference was statistically significant (χ2 =6.83, P 0.05).Conclusions The artificial nose can reduce the incidence rate of VAP , and decrease the nursing workload and the burden of patients to a certain extent . Key words: Artificial nose; Electric heating thermostat humidification jar; Pneumonia,ventilator-associated
Key concepts: Mechanical ventilation, Medicine, Thermostat, Pneumonia, Nose, Sputum, Incidence (geometry), Artificial lung