2020Fusion Science & TechnologyRequires access

Applicability of a 100-mL Polyethylene Vial for Low-Level Tritium Measurement Using a Low-Background Liquid Scintillation Counter

Yoshinari Oshimi, Mayu Ohki, Misato Nagano, Takuyo Yasumatsu, Masanori Hara, Satoshi Akamaru, Masato Nakayama, Miki Shoji

Open publisher page 2 citations

Abstract

For low-level tritium measurements using a liquid scintillation counter, scintillation vial selection is important. The applicability of polyethylene (PE) vials was studied. Three types of vials were tested: (1) 100-mL perfluoroalkoxy alkane (PFA) fluorine resin vials, (2) 100-mL PE vials, and (3) 145-mL PE vials. Ultima Gold LLT was the reference liquid scintillator in this study. The background counts for these vials were found to be 2.5 counts per minute. Tritiated water of 1.5 Bq‧mL−1 was employed as an internal standard to determine the counting efficiency. The counting efficiencies for the 100-mL PFA, 100-mL PE, and 145-mL PE vials were estimated to be 17%, 16%, and 13%, respectively. The lower limits of detection of these vials for a counting time of 100 min were 1.45 Bq‧L−1 for 100-mL PFA vials, 1.54 Bq‧L−1 for 100-mL PE vials, and 1.47 Bq‧L−1 for 145-mL PE vials. Thus, these vials demonstrate similar performances for tritium measurements.

About this research paper

What this paper is about

For low-level tritium measurements using a liquid scintillation counter, scintillation vial selection is important. The applicability of polyethylene (PE) vials was studied. Three types of vials were tested: (1) 100-mL perfluoroalkoxy alkane (PFA) fluorine resin vials, (2) 100-mL PE vials, and (3) 145-mL PE vials. Ultima Gold LLT was the reference liquid scintillator in this study. The background counts for these vials were found to be 2.5 counts per minute. Tritiated water of 1.5 Bq‧mL−1 was employed as an internal standard to determine the counting efficiency. The counting efficiencies for the 100-mL PFA, 100-mL PE, and 145-mL PE vials were estimated to be 17%, 16%, and 13%, respectively. The lower limits of detection of these vials for a counting time of 100 min were 1.45 Bq‧L−1 for 100-mL PFA vials, 1.54 Bq‧L−1 for 100-mL PE vials, and 1.47 Bq‧L−1 for 145-mL PE vials. Thus, these vials demonstrate similar performances for tritium measurements.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For low-level tritium measurements using a liquid scintillation counter, scintillation vial selection is important. The applicability of polyethylene (PE) vials was studied. Three types of vials were tested: (1) 100-mL perfluoroalkoxy alkane (PFA) fluorine resin vials, (2) 100-mL PE vials, and (3) 145-mL PE vials. Ultima Gold LLT was the reference liquid scintillator in this study. The background counts for these vials were found to be 2.5 counts per minute. Tritiated water of 1.5 Bq‧mL−1 was employed as an internal standard to determine the counting efficiency. The counting efficiencies for the 100-mL PFA, 100-mL PE, and 145-mL PE vials were estimated to be 17%, 16%, and 13%, respectively. The lower limits of detection of these vials for a counting time of 100 min were 1.45 Bq‧L−1 for 100-mL PFA vials, 1.54 Bq‧L−1 for 100-mL PE vials, and 1.47 Bq‧L−1 for 145-mL PE vials. Thus, these vials demonstrate similar performances for tritium measurements.

Key concepts: Tritium, Vial, Liquid scintillation counting, Materials science, Scintillation counter, Polyethylene, Nuclear engineering, Nuclear physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Applicability of a 100-mL Polyethylene Vial for Low-Level Tritium Measurement Using a Low-Background Liquid Scintillation Counter — Research Paper | ScholarLens