A Superconducting Wiggler Magnet for the NSLS X-Ray Ring.

E. Blum, D. R. Lynch, P. Mortazavi, Om V. Singh, W. Thomlinson, M. Woodle, Andrew Broadbent, M. C. Coates, S. Milward, E. J. F. Moor, K. Smith

Open full text 0 citations

Abstract

The superconducting 5 pole, 5 Tesla wiggler which has been operating in the X-17 straight section of the x-ray storage ring at the National Synchrotron Light Source (NSLS) since 1989 will soon be replaced by a new wiggler being built by Oxford Instruments with lower operating costs, higher reliability, and greater performance. The new wiggler has three modes of operation: the full wiggler with 11 poles producing 3.0 T, the partial wiggler with 5 poles at 4.7 T, and the wavelength shifter with a single pole producing 5.5 T. The full wiggler, optimized for the digital subtraction radiography program, will produce the same x-ray flux at the 33 KeV iodine K-edge as the existing wiggler operating at 4.7 T but will reduce the higher energy harmonics delivered to the target. The partial wiggler will deliver the same flux for solid state physics experiments as the existing wiggler, and the wavelength shifter will provide an elliptically polarized x-ray beam that is not now available. 1

About this research paper

What this paper is about

The superconducting 5 pole, 5 Tesla wiggler which has been operating in the X-17 straight section of the x-ray storage ring at the National Synchrotron Light Source (NSLS) since 1989 will soon be replaced by a new wiggler being built by Oxford Instruments with lower operating costs, higher reliability, and greater performance. The new wiggler has three modes of operation: the full wiggler with 11 poles producing 3.0 T, the partial wiggler with 5 poles at 4.7 T, and the wavelength shifter with a single pole producing 5.5 T. The full wiggler, optimized for the digital subtraction radiography program, will produce the same x-ray flux at the 33 KeV iodine K-edge as the existing wiggler operating at 4.7 T but will reduce the higher energy harmonics delivered to the target. The partial wiggler will deliver the same flux for solid state physics experiments as the existing wiggler, and the wavelength shifter will provide an elliptically polarized x-ray beam that is not now available. 1

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The superconducting 5 pole, 5 Tesla wiggler which has been operating in the X-17 straight section of the x-ray storage ring at the National Synchrotron Light Source (NSLS) since 1989 will soon be replaced by a new wiggler being built by Oxford Instruments with lower operating costs, higher reliability, and greater performance. The new wiggler has three modes of operation: the full wiggler with 11 poles producing 3.0 T, the partial wiggler with 5 poles at 4.7 T, and the wavelength shifter with a single pole producing 5.5 T. The full wiggler, optimized for the digital subtraction radiography program, will produce the same x-ray flux at the 33 KeV iodine K-edge as the existing wiggler operating at 4.7 T but will reduce the higher energy harmonics delivered to the target. The partial wiggler will deliver the same flux for solid state physics experiments as the existing wiggler, and the wavelength shifter will provide an elliptically polarized x-ray beam that is not now available. 1

Key concepts: Wiggler, Physics, Storage ring, Optics, Magnet, Synchrotron, Synchrotron radiation, Superconducting magnet

Related papers

Back to paper searchBrowse research topicsOriginal source
A Superconducting Wiggler Magnet for the NSLS X-Ray Ring. — Research Paper | ScholarLens