2011Journal of Applied Sports ScienceOpen access

Evaluating the Validity and Reliability of Harvard Step Test to Predict VO2max in Terms of the Step Height According to the Knee Joint Angle

Walid Soliman Ismail

Open full text 17 citations

Abstract

The purpose of this study was to evaluate and compare the validity and reliability of Harvard step test (HST) to predict the maximum oxygen uptake (Vo2max) through different methods, the first method via traditional Harvard step test (THST) with step height 50.8 cm, the second method by Multi-Height step according to the knee joint angle (KJAHST), where the researcher detects to Criterion-Related Validity between the two methods and the laboratory test via treadmill gas analysis system according to the established protocol ( ZAN 600 device ) , and in order to achieve the best method to predict (Vo2max) correct values through the Harvard step test in healthy college students, Participants (N = 120) age 20.06 ± 0.56 years, height 171.79 ± 5.83 cm, weight 70.39 ± 6.39 kg, the values of vo2max were calculated with the previous methods, the results showed that the value of correlation coefficient between (THST) and laboratory test was r = 0.818, while the value of correlation coefficient through (KJAHST) and the laboratory test was r = 0.905, which indicates that the two methods are valid to predict vo2max correct values, but the researcher recommended the usage of (KJAHST) method because it is more valid and accurate than (THST) , also there weren’t any significant differences between testing and re-testing for the second method (KJAHST) and the value of correlation coefficient was r = 0.913, so the researcher built Z-scores levels using the second method to be the standard in evaluating (Vo2max).

Open-access reader

About this research paper

What this paper is about

The purpose of this study was to evaluate and compare the validity and reliability of Harvard step test (HST) to predict the maximum oxygen uptake (Vo2max) through different methods, the first method via traditional Harvard step test (THST) with step height 50.8 cm, the second method by Multi-Height step according to the knee joint angle (KJAHST), where the researcher detects to Criterion-Related Validity between the two methods and the laboratory test via treadmill gas analysis system according to the established protocol ( ZAN 600 device ) , and in order to achieve the best method to predict (Vo2max) correct values through the Harvard step test in healthy college students, Participants (N = 120) age 20.06 ± 0.56 years, height 171.79 ± 5.83 cm, weight 70.39 ± 6.39 kg, the values of vo2max were calculated with the previous methods, the results showed that the value of correlation coefficient between (THST) and laboratory test was r = 0.818, while the value of correlation coefficient through (KJAHST) and the laboratory test was r = 0.905, which indicates that the two methods are valid to predict vo2max correct values, but the researcher recommended the usage of (KJAHST) method because it is more valid and accurate than (THST) , also there weren’t any significant differences between testing and re-testing for the second method (KJAHST) and the value of correlation coefficient was r = 0.913, so the researcher built Z-scores levels using the second method to be the standard in evaluating (Vo2max).

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to evaluate and compare the validity and reliability of Harvard step test (HST) to predict the maximum oxygen uptake (Vo2max) through different methods, the first method via traditional Harvard step test (THST) with step height 50.8 cm, the second method by Multi-Height step according to the knee joint angle (KJAHST), where the researcher detects to Criterion-Related Validity between the two methods and the laboratory test via treadmill gas analysis system according to the established protocol ( ZAN 600 device ) , and in order to achieve the best method to predict (Vo2max) correct values through the Harvard step test in healthy college students, Participants (N = 120) age 20.06 ± 0.56 years, height 171.79 ± 5.83 cm, weight 70.39 ± 6.39 kg, the values of vo2max were calculated with the previous methods, the results showed that the value of correlation coefficient between (THST) and laboratory test was r = 0.818, while the value of correlation coefficient through (KJAHST) and the laboratory test was r = 0.905, which indicates that the two methods are valid to predict vo2max correct values, but the researcher recommended the usage of (KJAHST) method because it is more valid and accurate than (THST) , also there weren’t any significant differences between testing and re-testing for the second method (KJAHST) and the value of correlation coefficient was r = 0.913, so the researcher built Z-scores levels using the second method to be the standard in evaluating (Vo2max).

Key concepts: Reliability (semiconductor), Test (biology), Step test, Joint (building), Reliability engineering, Statistics, Mathematics, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluating the Validity and Reliability of Harvard Step Test to Predict VO2max in Terms of the Step Height According to the Knee Joint Angle — Research Paper | ScholarLens