Comparison of Conventional Keratometry and Total Keratometry in Normal Eyes

Rie Hoshikawa, Kazutaka Kamiya, Fusako Fujimura, Nobuyuki Shoji

Open full text 22 citations

Abstract

Purpose. The relationship between conventional keratometry and total keratometry has not been fully investigated. This study was aimed at conventional keratometry measured with the automated keratometer and total keratometry with the corneal tomographer in ophthalmologically normal subjects. Methods. We enrolled fifty eyes of 50 consecutive subjects (mean age ± standard deviation, 34.9 ± 8.0 years) who have no ophthalmologic diseases, other than refractive errors, with no history of ocular surgery. Conventional keratometry was measured with the automated keratometer. The total keratometry, the true net power (TNP), and the total corneal refractive power (TCRP) were measured with the Scheimpflug camera, and the real power (RP) was measured with anterior segment optical coherence tomography (As‐OCT). Anterior keratometries (Km and AvgK) were also measured with the Scheimpflug camera and the As‐OCT, respectively. Results. Conventional keratometry was 43.64 ± 1.48 D, which was significantly higher than the TCRP (42.94 ± 1.45 D, p = 0.042), the TNP (42.13 ± 1.37 D, p < 0.001), and the RP (42.62 ± 1.39 D, p = 0.001, Dunnett’s test). We found significant correlations between conventional keratometry and each total corneal power (the TCRP (Pearson’s correlation coefficient r = 0.986, p < 0.001), the TNP (r = 0.986, p < 0.001), the RP (r = 0.987, p < 0.001), the Km (r = 0.990, p < 0.001), and the AvgK (r = 0.991, p < 0.001)). The intraclass correlations of conventional keratometry with the TCRP, the TNP, the RP, the Km, and the AvgK were 0.986, 0.983, 0.985, 0.990, and 0.990, respectively. We found no significant differences in the keratometric data measured with the automated keratometer, the Scheimpflug camera, and the As‐OCT (ANOVA, p = 0.729). Conclusions. Conventional keratometry was significantly larger than total keratometry, by approximately 0.70 to 1.52 D, in ophthalmologically normal subjects. By contrast, there were no significant differences in the keratometric data among the three devices. It is suggested that conventional keratometry overestimates the total corneal power in daily practice.

Open-access reader

About this research paper

What this paper is about

Purpose. The relationship between conventional keratometry and total keratometry has not been fully investigated. This study was aimed at conventional keratometry measured with the automated keratometer and total keratometry with the corneal tomographer in ophthalmologically normal subjects. Methods. We enrolled fifty eyes of 50 consecutive subjects (mean age ± standard deviation, 34.9 ± 8.0 years) who have no ophthalmologic diseases, other than refractive errors, with no history of ocular surgery. Conventional keratometry was measured with the automated keratometer. The total keratometry, the true net power (TNP), and the total corneal refractive power (TCRP) were measured with the Scheimpflug camera, and the real power (RP) was measured with anterior segment optical coherence tomography (As‐OCT). Anterior keratometries (Km and AvgK) were also measured with the Scheimpflug camera and the As‐OCT, respectively. Results. Conventional keratometry was 43.64 ± 1.48 D, which was significantly higher than the TCRP (42.94 ± 1.45 D, p = 0.042), the TNP (42.13 ± 1.37 D, p < 0.001), and the RP (42.62 ± 1.39 D, p = 0.001, Dunnett’s test). We found significant correlations between conventional keratometry and each total corneal power (the TCRP (Pearson’s correlation coefficient r = 0.986, p < 0.001), the TNP (r = 0.986, p < 0.001), the RP (r = 0.987, p < 0.001), the Km (r = 0.990, p < 0.001), and the AvgK (r = 0.991, p < 0.001)). The intraclass correlations of conventional keratometry with the TCRP, the TNP, the RP, the Km, and the AvgK were 0.986, 0.983, 0.985, 0.990, and 0.990, respectively. We found no significant differences in the keratometric data measured with the automated keratometer, the Scheimpflug camera, and the As‐OCT (ANOVA, p = 0.729). Conclusions. Conventional keratometry was significantly larger than total keratometry, by approximately 0.70 to 1.52 D, in ophthalmologically normal subjects. By contrast, there were no significant differences in the keratometric data among the three devices. It is suggested that conventional keratometry overestimates the total corneal power in daily practice.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose. The relationship between conventional keratometry and total keratometry has not been fully investigated. This study was aimed at conventional keratometry measured with the automated keratometer and total keratometry with the corneal tomographer in ophthalmologically normal subjects. Methods. We enrolled fifty eyes of 50 consecutive subjects (mean age ± standard deviation, 34.9 ± 8.0 years) who have no ophthalmologic diseases, other than refractive errors, with no history of ocular surgery. Conventional keratometry was measured with the automated keratometer. The total keratometry, the true net power (TNP), and the total corneal refractive power (TCRP) were measured with the Scheimpflug camera, and the real power (RP) was measured with anterior segment optical coherence tomography (As‐OCT). Anterior keratometries (Km and AvgK) were also measured with the Scheimpflug camera and the As‐OCT, respectively. Results. Conventional keratometry was 43.64 ± 1.48 D, which was significantly higher than the TCRP (42.94 ± 1.45 D, p = 0.042), the TNP (42.13 ± 1.37 D, p < 0.001), and the RP (42.62 ± 1.39 D, p = 0.001, Dunnett’s test). We found significant correlations between conventional keratometry and each total corneal power (the TCRP (Pearson’s correlation coefficient r = 0.986, p < 0.001), the TNP (r = 0.986, p < 0.001), the RP (r = 0.987, p < 0.001), the Km (r = 0.990, p < 0.001), and the AvgK (r = 0.991, p < 0.001)). The intraclass correlations of conventional keratometry with the TCRP, the TNP, the RP, the Km, and the AvgK were 0.986, 0.983, 0.985, 0.990, and 0.990, respectively. We found no significant differences in the keratometric data measured with the automated keratometer, the Scheimpflug camera, and the As‐OCT (ANOVA, p = 0.729). Conclusions. Conventional keratometry was significantly larger than total keratometry, by approximately 0.70 to 1.52 D, in ophthalmologically normal subjects. By contrast, there were no significant differences in the keratometric data among the three devices. It is suggested that conventional keratometry overestimates the total corneal power in daily practice.

Key concepts: Keratometer, Scheimpflug principle, Intraclass correlation, Ophthalmology, Medicine, Corneal topography, Mathematics, Optometry