HEURISTIC METHODE FOR OPTIMIZING POWER LOAD FLOW ANALYSIS IN ELECTRICAL POWER SYSTEM

Anh Huy Quyen, Trương Việt Anh, Huong Thi Thanh

Open full text 0 citations

Abstract

The primary goal of a generic optimal power load flow problem Is minimizing total fuel costs of generating units in an electrical power system while maintaining the security of the system. This paper presents an algorithm for optimizing power load flow analysis through the application of Newton ’s method and attends to interchange power between the different power systems. Specifically, it will explore the implementation of data structure such as the binary tree in searching OPF variables (controls, states, constraints) in large power system. So the OPF solution is quickly converging. The primary goal of a generic OFF has been tested by simulation method for 6- bus system in Power World environment. The optimal power flow results is shown that total generation fuel cost in the interchange power case is less expensive than in no interchange power case as well as total transmission losses in the power system are smaller.

Open-access reader

About this research paper

What this paper is about

The primary goal of a generic optimal power load flow problem Is minimizing total fuel costs of generating units in an electrical power system while maintaining the security of the system. This paper presents an algorithm for optimizing power load flow analysis through the application of Newton ’s method and attends to interchange power between the different power systems. Specifically, it will explore the implementation of data structure such as the binary tree in searching OPF variables (controls, states, constraints) in large power system. So the OPF solution is quickly converging. The primary goal of a generic OFF has been tested by simulation method for 6- bus system in Power World environment. The optimal power flow results is shown that total generation fuel cost in the interchange power case is less expensive than in no interchange power case as well as total transmission losses in the power system are smaller.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The primary goal of a generic optimal power load flow problem Is minimizing total fuel costs of generating units in an electrical power system while maintaining the security of the system. This paper presents an algorithm for optimizing power load flow analysis through the application of Newton ’s method and attends to interchange power between the different power systems. Specifically, it will explore the implementation of data structure such as the binary tree in searching OPF variables (controls, states, constraints) in large power system. So the OPF solution is quickly converging. The primary goal of a generic OFF has been tested by simulation method for 6- bus system in Power World environment. The optimal power flow results is shown that total generation fuel cost in the interchange power case is less expensive than in no interchange power case as well as total transmission losses in the power system are smaller.

Key concepts: Electric power system, Power-flow study, Power (physics), Computer science, Power flow, Electricity generation, Electric power, Heuristic

Related papers

Back to paper searchBrowse research topicsOriginal source
HEURISTIC METHODE FOR OPTIMIZING POWER LOAD FLOW ANALYSIS IN ELECTRICAL POWER SYSTEM — Research Paper | ScholarLens