2020TELKOMNIKA (Telecommunication Computing Electronics and Control)Open access

Design of shunt hybrid active power filter for compensating harmonic currents and reactive power

Ibrahim Alhamrouni, F. Hanafi, Mohamed Salem, Nadia Hanis Abd Rahman, Awang Jusoh, Tole Sutikno

Open full text 6 citations

Abstract

For the past two decades, tremendous advancements have been achieved in the electricity industry. The usage of non-linear loads in the daily life has affected the power quality of the system and caused the presence of harmonics. To compensate the harmonic currents and reactive power in the system, the design of shunt hybrid active power filter has been proposed in this research. The design of the filter has included several control systems of instantaneous active and reactive power (p-q) theory and PI controller to investigate the performance of the filter. The robustness of the designed hybrid power filter has also been benchmarked with the other filter topologies available in literature. The hybrid power filter will combine passive power filter and active power filter configurated in shunt connection. The result of this research showed that the total harmonic distortion analyzed is below than 5% according to IEEE-519 standard requirements and reactive power is compensated proved by the increase in power factor. The shunt hybrid active power filter is designed, and simulation result is analyzed by using MATLAB-Simulink environment.

About this research paper

What this paper is about

For the past two decades, tremendous advancements have been achieved in the electricity industry. The usage of non-linear loads in the daily life has affected the power quality of the system and caused the presence of harmonics. To compensate the harmonic currents and reactive power in the system, the design of shunt hybrid active power filter has been proposed in this research. The design of the filter has included several control systems of instantaneous active and reactive power (p-q) theory and PI controller to investigate the performance of the filter. The robustness of the designed hybrid power filter has also been benchmarked with the other filter topologies available in literature. The hybrid power filter will combine passive power filter and active power filter configurated in shunt connection. The result of this research showed that the total harmonic distortion analyzed is below than 5% according to IEEE-519 standard requirements and reactive power is compensated proved by the increase in power factor. The shunt hybrid active power filter is designed, and simulation result is analyzed by using MATLAB-Simulink environment.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For the past two decades, tremendous advancements have been achieved in the electricity industry. The usage of non-linear loads in the daily life has affected the power quality of the system and caused the presence of harmonics. To compensate the harmonic currents and reactive power in the system, the design of shunt hybrid active power filter has been proposed in this research. The design of the filter has included several control systems of instantaneous active and reactive power (p-q) theory and PI controller to investigate the performance of the filter. The robustness of the designed hybrid power filter has also been benchmarked with the other filter topologies available in literature. The hybrid power filter will combine passive power filter and active power filter configurated in shunt connection. The result of this research showed that the total harmonic distortion analyzed is below than 5% according to IEEE-519 standard requirements and reactive power is compensated proved by the increase in power factor. The shunt hybrid active power filter is designed, and simulation result is analyzed by using MATLAB-Simulink environment.

Key concepts: AC power, Active filter, Power factor, Harmonics, Control theory (sociology), Total harmonic distortion, Voltage-controlled filter, Electronic engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of shunt hybrid active power filter for compensating harmonic currents and reactive power — Research Paper | ScholarLens