2020Optics ExpressOpen access

On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellite using three independent methods

Yaokai Liu, Lingling Ma, Ning Wang, Yonggang Qian, Yongguang Zhao, Shi Qiu, Caixia Gao, Xiaoxiang Long, Chuanrong Li

Open full text 21 citations

Abstract

On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellites is the foundation for further quantitative applications. A field calibration campaign was orchestrated to radiometrically calibrate the SuperView-1 optical sensors at the Baotou calibration site in China during September 2018. Based on the collected datasets, three independent methods (reflectance-based, radiance-based, and cross-calibration) were used to determine the radiometric calibration coefficients of the SuperView-1 optical sensors with multiple permanent artificial calibration targets. Comparisons of the desert top-of-atmosphere radiance calculated based on the coefficients determined with independent methods were analyzed. Comparison results show that the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 1.26% and 4.23% for SV0102 and SV0104, respectively. While, the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 0.82% and 6.83% for SV0101 and SV0103, respectively. The reasonably good agreement of the radiometrically calibrated coefficients of the SuperView-1 on-board sensors between these independent methods is encouraging. An uncertainty analysis was also discussed, and the results suggest that the overall uncertainties of the predicted TOA radiance are less than 4.5%, 4.0%, and 5.15% for the reflectance-based, radiance-based, and cross-calibration methods, respectively.

About this research paper

What this paper is about

On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellites is the foundation for further quantitative applications. A field calibration campaign was orchestrated to radiometrically calibrate the SuperView-1 optical sensors at the Baotou calibration site in China during September 2018. Based on the collected datasets, three independent methods (reflectance-based, radiance-based, and cross-calibration) were used to determine the radiometric calibration coefficients of the SuperView-1 optical sensors with multiple permanent artificial calibration targets. Comparisons of the desert top-of-atmosphere radiance calculated based on the coefficients determined with independent methods were analyzed. Comparison results show that the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 1.26% and 4.23% for SV0102 and SV0104, respectively. While, the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 0.82% and 6.83% for SV0101 and SV0103, respectively. The reasonably good agreement of the radiometrically calibrated coefficients of the SuperView-1 on-board sensors between these independent methods is encouraging. An uncertainty analysis was also discussed, and the results suggest that the overall uncertainties of the predicted TOA radiance are less than 4.5%, 4.0%, and 5.15% for the reflectance-based, radiance-based, and cross-calibration methods, respectively.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellites is the foundation for further quantitative applications. A field calibration campaign was orchestrated to radiometrically calibrate the SuperView-1 optical sensors at the Baotou calibration site in China during September 2018. Based on the collected datasets, three independent methods (reflectance-based, radiance-based, and cross-calibration) were used to determine the radiometric calibration coefficients of the SuperView-1 optical sensors with multiple permanent artificial calibration targets. Comparisons of the desert top-of-atmosphere radiance calculated based on the coefficients determined with independent methods were analyzed. Comparison results show that the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 1.26% and 4.23% for SV0102 and SV0104, respectively. While, the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 0.82% and 6.83% for SV0101 and SV0103, respectively. The reasonably good agreement of the radiometrically calibrated coefficients of the SuperView-1 on-board sensors between these independent methods is encouraging. An uncertainty analysis was also discussed, and the results suggest that the overall uncertainties of the predicted TOA radiance are less than 4.5%, 4.0%, and 5.15% for the reflectance-based, radiance-based, and cross-calibration methods, respectively.

Key concepts: Radiance, Remote sensing, Radiometric calibration, Calibration, Satellite, Environmental science, Radiometry, Sun photometer

Related papers

Back to paper searchBrowse research topicsOriginal source
On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellite using three independent methods — Research Paper | ScholarLens