2012Remote Sensing InformationRequires access

HJ-1B Thermal Infrared Band In-flight Radiometric Calibration

Li Liu

Open publisher page 0 citations

Abstract

This paper described that in-flight radiometric calibration for thermal bands of HJ-1B using the test site Qinghai-lake.The radiance of water surface was measured by CE312,and the spectral transmittance and upward radiance of the atmosphere was calculated using radiance transfer model MODTRAN4.0.At the same time the spectral response of HJ-1B sensor and that of CE312 sensor are coupled.The calibration coefficient is given by the comparison between the apparent radiance of sensor and the digital count of satellite's output from the data of Aug.1 and 5,2010.The results are validated by the data of June 29,2010 at the Dali-lake test site.

About this research paper

What this paper is about

This paper described that in-flight radiometric calibration for thermal bands of HJ-1B using the test site Qinghai-lake.The radiance of water surface was measured by CE312,and the spectral transmittance and upward radiance of the atmosphere was calculated using radiance transfer model MODTRAN4.0.At the same time the spectral response of HJ-1B sensor and that of CE312 sensor are coupled.The calibration coefficient is given by the comparison between the apparent radiance of sensor and the digital count of satellite's output from the data of Aug.1 and 5,2010.The results are validated by the data of June 29,2010 at the Dali-lake test site.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper described that in-flight radiometric calibration for thermal bands of HJ-1B using the test site Qinghai-lake.The radiance of water surface was measured by CE312,and the spectral transmittance and upward radiance of the atmosphere was calculated using radiance transfer model MODTRAN4.0.At the same time the spectral response of HJ-1B sensor and that of CE312 sensor are coupled.The calibration coefficient is given by the comparison between the apparent radiance of sensor and the digital count of satellite's output from the data of Aug.1 and 5,2010.The results are validated by the data of June 29,2010 at the Dali-lake test site.

Key concepts: Radiance, Remote sensing, Radiometric calibration, Calibration, Environmental science, Satellite, Infrared, Transmittance

Related papers

Back to paper searchBrowse research topicsOriginal source
HJ-1B Thermal Infrared Band In-flight Radiometric Calibration — Research Paper | ScholarLens