2020Peritoneal Dialysis InternationalRequires access

Estimating total small solute clearance in patients treated with continuous ambulatory peritoneal dialysis without urine and dialysate collection

Li Fan, Dominik Steubl, Lesley A. Inker, Hocine Tighiouart, Andrew Simon, Meredith C. Foster, Amy B. Karger, John H. Eckfeldt, Hongyan Li, Jiamin Tang, Yongcheng He, Minyan Xie, Fei Xiong, Hongbo Li, Hao Zhang, Jing Hu, Yunhua Liao, Xudong Ye, Tariq Shafi, Wei Chen, Xueqing Yu, Andrew S. Levey

Open publisher page 3 citations

Abstract

Background: International Society for Peritoneal Dialysis guidelines recommend to routinely monitor the total measured clearance (mCl) of small solutes such as creatinine; however, collection of 24-h urine and peritoneal dialysis (PD) fluid is burdensome to patients and prone to errors. We hypothesized that equations could be developed to estimate mCl (estimated clearance (eCl)) using endogenous filtration markers. Methods: In the Guangzhou PD Study ( n = 980), we developed eCl equations using linear regression in two-third and validated them in the remaining one-third. Reference tests were mCl for urea nitrogen (UN) (mCl UN , ml/min) and average mCl for UN and creatinine (mCl UN-cr , ml/min/1.73 m 2 ). Index tests were various eCl equations using UN, creatinine, low-molecular-weight proteins (LMWPs) (beta-trace protein (BTP), beta-2 microglobulin (B2M), and cystatin C), demographic variables, and body size. After reexpression of the equations in the combined data set, we analyzed accuracy (eCl within ± 2.0 units of mCl) and the predictive value of eCl to detect a weekly total standard Kt/V (weekly mCl UN indexed for total body water) > 1.7 using receiver operating characteristic curve. Results: Mean age of the cohort was 50 ± 15 years, 53% were male; mCl UN was 6.9 ± 1.8 and mCl UN-cr was 7.5 ± 2.8. Creatinine but not UN contributed to eCl for both mCl. LMWP did not improve accuracy for mCl UN (range 88–89%). BTP and B2M improved the accuracy for mCl UN-cr (82% vs. 80%); however, differences were small. The area under the curve for predicting a weekly Kt/V > 1.7 was similar for all equations (range 0.79–0.80). Conclusions: Total small solute clearance can be estimated moderately well in continuous ambulatory PD patients using serum creatinine and demographic variables without urine and dialysate collection.

About this research paper

What this paper is about

Background: International Society for Peritoneal Dialysis guidelines recommend to routinely monitor the total measured clearance (mCl) of small solutes such as creatinine; however, collection of 24-h urine and peritoneal dialysis (PD) fluid is burdensome to patients and prone to errors. We hypothesized that equations could be developed to estimate mCl (estimated clearance (eCl)) using endogenous filtration markers. Methods: In the Guangzhou PD Study ( n = 980), we developed eCl equations using linear regression in two-third and validated them in the remaining one-third. Reference tests were mCl for urea nitrogen (UN) (mCl UN , ml/min) and average mCl for UN and creatinine (mCl UN-cr , ml/min/1.73 m 2 ). Index tests were various eCl equations using UN, creatinine, low-molecular-weight proteins (LMWPs) (beta-trace protein (BTP), beta-2 microglobulin (B2M), and cystatin C), demographic variables, and body size. After reexpression of the equations in the combined data set, we analyzed accuracy (eCl within ± 2.0 units of mCl) and the predictive value of eCl to detect a weekly total standard Kt/V (weekly mCl UN indexed for total body water) > 1.7 using receiver operating characteristic curve. Results: Mean age of the cohort was 50 ± 15 years, 53% were male; mCl UN was 6.9 ± 1.8 and mCl UN-cr was 7.5 ± 2.8. Creatinine but not UN contributed to eCl for both mCl. LMWP did not improve accuracy for mCl UN (range 88–89%). BTP and B2M improved the accuracy for mCl UN-cr (82% vs. 80%); however, differences were small. The area under the curve for predicting a weekly Kt/V > 1.7 was similar for all equations (range 0.79–0.80). Conclusions: Total small solute clearance can be estimated moderately well in continuous ambulatory PD patients using serum creatinine and demographic variables without urine and dialysate collection.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: International Society for Peritoneal Dialysis guidelines recommend to routinely monitor the total measured clearance (mCl) of small solutes such as creatinine; however, collection of 24-h urine and peritoneal dialysis (PD) fluid is burdensome to patients and prone to errors. We hypothesized that equations could be developed to estimate mCl (estimated clearance (eCl)) using endogenous filtration markers. Methods: In the Guangzhou PD Study ( n = 980), we developed eCl equations using linear regression in two-third and validated them in the remaining one-third. Reference tests were mCl for urea nitrogen (UN) (mCl UN , ml/min) and average mCl for UN and creatinine (mCl UN-cr , ml/min/1.73 m 2 ). Index tests were various eCl equations using UN, creatinine, low-molecular-weight proteins (LMWPs) (beta-trace protein (BTP), beta-2 microglobulin (B2M), and cystatin C), demographic variables, and body size. After reexpression of the equations in the combined data set, we analyzed accuracy (eCl within ± 2.0 units of mCl) and the predictive value of eCl to detect a weekly total standard Kt/V (weekly mCl UN indexed for total body water) > 1.7 using receiver operating characteristic curve. Results: Mean age of the cohort was 50 ± 15 years, 53% were male; mCl UN was 6.9 ± 1.8 and mCl UN-cr was 7.5 ± 2.8. Creatinine but not UN contributed to eCl for both mCl. LMWP did not improve accuracy for mCl UN (range 88–89%). BTP and B2M improved the accuracy for mCl UN-cr (82% vs. 80%); however, differences were small. The area under the curve for predicting a weekly Kt/V > 1.7 was similar for all equations (range 0.79–0.80). Conclusions: Total small solute clearance can be estimated moderately well in continuous ambulatory PD patients using serum creatinine and demographic variables without urine and dialysate collection.

Key concepts: Medicine, Peritoneal dialysis, Creatinine, Renal function, Urology, Cystatin C, Receiver operating characteristic, Urine

Related papers

Back to paper searchBrowse research topicsOriginal source
Estimating total small solute clearance in patients treated with continuous ambulatory peritoneal dialysis without urine and dialysate collection — Research Paper | ScholarLens