Highly Sensitive Determination of Bisphenol A in Bottled Water Samples by HPLC after Its Extraction by a Novel Th-MOF Pipette-Tip Micro-SPE

Massoud Kaykhaii, Eilnaz Yavari, Ghasem Sargazi, A. Ebrahimi

Open publisher page 38 citations

Abstract

In this study, a novel thorium metal organic framework was synthesized, characterized and used as a sorbent for very efficient pipette tip micro solid-phase extraction of bisphenol A in bottled drinking water samples using high-performance liquid chromatography as detecting instrument. Parameters which influence extraction efficiency such as pH, sample volume, amount of sorbent, type and volume of eluent, number of aspirating and dispensing cycles for extraction and elution, and volume of the sample solution were studied and optimized. A linear calibration curve was obtained in the range of 0.002-0.456 ng mL-1 (r2 = 0.996) with a detection limit of 0.0010 ng mL-1. Repeatability of batch-to-batch extraction was better than 5.0% and a reproducibility of 3.2% for real samples obtained.

About this research paper

What this paper is about

In this study, a novel thorium metal organic framework was synthesized, characterized and used as a sorbent for very efficient pipette tip micro solid-phase extraction of bisphenol A in bottled drinking water samples using high-performance liquid chromatography as detecting instrument. Parameters which influence extraction efficiency such as pH, sample volume, amount of sorbent, type and volume of eluent, number of aspirating and dispensing cycles for extraction and elution, and volume of the sample solution were studied and optimized. A linear calibration curve was obtained in the range of 0.002-0.456 ng mL-1 (r2 = 0.996) with a detection limit of 0.0010 ng mL-1. Repeatability of batch-to-batch extraction was better than 5.0% and a reproducibility of 3.2% for real samples obtained.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, a novel thorium metal organic framework was synthesized, characterized and used as a sorbent for very efficient pipette tip micro solid-phase extraction of bisphenol A in bottled drinking water samples using high-performance liquid chromatography as detecting instrument. Parameters which influence extraction efficiency such as pH, sample volume, amount of sorbent, type and volume of eluent, number of aspirating and dispensing cycles for extraction and elution, and volume of the sample solution were studied and optimized. A linear calibration curve was obtained in the range of 0.002-0.456 ng mL-1 (r2 = 0.996) with a detection limit of 0.0010 ng mL-1. Repeatability of batch-to-batch extraction was better than 5.0% and a reproducibility of 3.2% for real samples obtained.