2019•PubMedRequires access

[Efficacy of electroacupuncture combined with penetrating moxibustion for postpartum stress urinary incontinence].

Lin-Lin Wang, Zhixin Ren, Jing-Yun Zhu, Hailing Zhang, Yan-Rong Wu

Open publisher page 12 citations

Abstract

OBJECTIVE: To compare the clinical effect differences between electroacupuncture (EA) combined with penetrating moxibustion and the biological feedback training of pelvic floor muscle for postpartum stress urinary incontinence (SUI). METHODS: Sixty patients of SUI who had delivery 42 days ago were randomly divided into an observation group and a control group, 30 cases in each one. The observation group was treated with EA and penetrating moxibustion. EA was applied at Ciliao (BL 32) and Huiyang (BL 35), combined with acupuncture at Qihai (CV 6), Zhongji (CV 3), Zigong (EX-CA 1), Zusanli (ST 36) and Sanyinjiao (SP 6); penetrating moxibustion was performed on abdomen and lumbosacral area. The control group was treated with biological feedback training of pelvic floor muscle. Both the groups were treated once every other day, 3 times per week for continuous 6 weeks. The International Consultation on Incontinence Questionnaire-Short Form (ICI-Q-SF), 1 h urinal pad test and pelvic floor muscle strength were tested before and after treatment; the efficacy was evaluated after treatment and at 6-month follow-up visit. RESULTS: <0.05). CONCLUSION: EA combined with penetrating moxibustion could improve the urinary control ability, relieve the symptoms of urinary incontinence and have a better long-term effect in patients with postpartum SUI, which is superior to biological feedback training of pelvic floor muscle.

About this research paper

What this paper is about

OBJECTIVE: To compare the clinical effect differences between electroacupuncture (EA) combined with penetrating moxibustion and the biological feedback training of pelvic floor muscle for postpartum stress urinary incontinence (SUI). METHODS: Sixty patients of SUI who had delivery 42 days ago were randomly divided into an observation group and a control group, 30 cases in each one. The observation group was treated with EA and penetrating moxibustion. EA was applied at Ciliao (BL 32) and Huiyang (BL 35), combined with acupuncture at Qihai (CV 6), Zhongji (CV 3), Zigong (EX-CA 1), Zusanli (ST 36) and Sanyinjiao (SP 6); penetrating moxibustion was performed on abdomen and lumbosacral area. The control group was treated with biological feedback training of pelvic floor muscle. Both the groups were treated once every other day, 3 times per week for continuous 6 weeks. The International Consultation on Incontinence Questionnaire-Short Form (ICI-Q-SF), 1 h urinal pad test and pelvic floor muscle strength were tested before and after treatment; the efficacy was evaluated after treatment and at 6-month follow-up visit. RESULTS: <0.05). CONCLUSION: EA combined with penetrating moxibustion could improve the urinary control ability, relieve the symptoms of urinary incontinence and have a better long-term effect in patients with postpartum SUI, which is superior to biological feedback training of pelvic floor muscle.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To compare the clinical effect differences between electroacupuncture (EA) combined with penetrating moxibustion and the biological feedback training of pelvic floor muscle for postpartum stress urinary incontinence (SUI). METHODS: Sixty patients of SUI who had delivery 42 days ago were randomly divided into an observation group and a control group, 30 cases in each one. The observation group was treated with EA and penetrating moxibustion. EA was applied at Ciliao (BL 32) and Huiyang (BL 35), combined with acupuncture at Qihai (CV 6), Zhongji (CV 3), Zigong (EX-CA 1), Zusanli (ST 36) and Sanyinjiao (SP 6); penetrating moxibustion was performed on abdomen and lumbosacral area. The control group was treated with biological feedback training of pelvic floor muscle. Both the groups were treated once every other day, 3 times per week for continuous 6 weeks. The International Consultation on Incontinence Questionnaire-Short Form (ICI-Q-SF), 1 h urinal pad test and pelvic floor muscle strength were tested before and after treatment; the efficacy was evaluated after treatment and at 6-month follow-up visit. RESULTS: <0.05). CONCLUSION: EA combined with penetrating moxibustion could improve the urinary control ability, relieve the symptoms of urinary incontinence and have a better long-term effect in patients with postpartum SUI, which is superior to biological feedback training of pelvic floor muscle.

Key concepts: Zusanli, Medicine, Electroacupuncture, Moxibustion, Urinary incontinence, Pelvic Floor Muscle, Pelvic floor, Acupuncture

Related papers

Back to paper searchBrowse research topicsOriginal source
[Efficacy of electroacupuncture combined with penetrating moxibustion for postpartum stress urinary incontinence]. — Research Paper | ScholarLens