2019MM Science JournalOpen access

REVIEW OF SIPHONIC ROOF DRAINAGE SYSTEMS

David Fucik, Jan Ručka

Open full text 3 citations

Abstract

The article describes an introduction to the problem of drainage of flat roofs, namely by using a vacuum drainage system.The article describes the current state, which also describes the gravity drainage system, whose design is in partial "retreat", unless required by local conditions or the investor of the construction.The following describes the advantages and disadvantages of the vacuum system and some design principles.The fourth chapter deals with the most common problems of the system, which include hydraulic system alignment, where the correct design of the system is carried out by hydraulic calculation of the system branches, using special software.The vacuum system must be designed in the correct dimensions, with suitable outlets and in such a way that it is not adversely affected by eg obstacles on the roof.Other mentioned problems include the level of noise and vibration of the system, which arises especially at higher intensity of rainfall, which leads to fluctuations between gravity and vacuum mode of water flow in the pipeline.These problems will be solved in the following research activity.Laboratory testing of hydraulic quantities and other parameters will be performed on a test equipment.The measured results will be further evaluated.

Open-access reader

About this research paper

What this paper is about

The article describes an introduction to the problem of drainage of flat roofs, namely by using a vacuum drainage system.The article describes the current state, which also describes the gravity drainage system, whose design is in partial "retreat", unless required by local conditions or the investor of the construction.The following describes the advantages and disadvantages of the vacuum system and some design principles.The fourth chapter deals with the most common problems of the system, which include hydraulic system alignment, where the correct design of the system is carried out by hydraulic calculation of the system branches, using special software.The vacuum system must be designed in the correct dimensions, with suitable outlets and in such a way that it is not adversely affected by eg obstacles on the roof.Other mentioned problems include the level of noise and vibration of the system, which arises especially at higher intensity of rainfall, which leads to fluctuations between gravity and vacuum mode of water flow in the pipeline.These problems will be solved in the following research activity.Laboratory testing of hydraulic quantities and other parameters will be performed on a test equipment.The measured results will be further evaluated.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The article describes an introduction to the problem of drainage of flat roofs, namely by using a vacuum drainage system.The article describes the current state, which also describes the gravity drainage system, whose design is in partial "retreat", unless required by local conditions or the investor of the construction.The following describes the advantages and disadvantages of the vacuum system and some design principles.The fourth chapter deals with the most common problems of the system, which include hydraulic system alignment, where the correct design of the system is carried out by hydraulic calculation of the system branches, using special software.The vacuum system must be designed in the correct dimensions, with suitable outlets and in such a way that it is not adversely affected by eg obstacles on the roof.Other mentioned problems include the level of noise and vibration of the system, which arises especially at higher intensity of rainfall, which leads to fluctuations between gravity and vacuum mode of water flow in the pipeline.These problems will be solved in the following research activity.Laboratory testing of hydraulic quantities and other parameters will be performed on a test equipment.The measured results will be further evaluated.

Key concepts: Roof, Drainage, Drainage system (geomorphology), Geology, Engineering, Civil engineering, Ecology, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
REVIEW OF SIPHONIC ROOF DRAINAGE SYSTEMS — Research Paper | ScholarLens