Effect of Third-generation Dual-source CT Technology on Image Quality of Low-dose Chest CT.
Xin Sui, Xiaoli Xu, Lan Song, Qianni Du, Xiao Wang, Zheng-yu Jing, Wei Song
Abstract
Xin Sui, Xiaoli Xu, Lan Song, Qianni Du, Xiao Wang, Zheng-yu Jing, Wei Song
Abstract
Objective To evaluate the image quality and radiation dose of third-generation dual-source CT with tin filtration for spectral shaping and iterative reconstructions.Methods Thirty-five patients underwent low-dose CT (LDCT) for lung cancer screening on second-generation dual-source CT and follow-ups on third-generation dual-source CT. Image quality and radiation dose were compared between the two examinations.ResultsThe radiation dose of third-generation dual-source CT [dose-length product (DLP)(49.7±18.2)mGy·cm, effective dose (ED)(0.73±0.26)mSv] was lower than second-generation dual-source CT [DLP (86.37±13.44) mGy·cm, ED(1.20±0.42)mSv](t=6.01, P=0.000;t=6.57, P=0.000). The objective image noise of second-generation dual-source CT [(25.7±2.9)HU] was higher than that of third-generation dual-soure CT[(18.6±4.2)HU](t=5.24,P=0.000).The subjective image noise of second-generation dual-source CT [(4.60±0.49)scores] was significantly lower than that of third-generation dual-source CT [(4.80±0.40)scores] (t=4.15, P=0.000). Conclusion Chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT that produces high image quality and low radiation dose when using a stellar infinity detector with spectral shaping.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the image quality and radiation dose of third-generation dual-source CT with tin filtration for spectral shaping and iterative reconstructions.Methods Thirty-five patients underwent low-dose CT (LDCT) for lung cancer screening on second-generation dual-source CT and follow-ups on third-generation dual-source CT. Image quality and radiation dose were compared between the two examinations.ResultsThe radiation dose of third-generation dual-source CT [dose-length product (DLP)(49.7±18.2)mGy·cm, effective dose (ED)(0.73±0.26)mSv] was lower than second-generation dual-source CT [DLP (86.37±13.44) mGy·cm, ED(1.20±0.42)mSv](t=6.01, P=0.000;t=6.57, P=0.000). The objective image noise of second-generation dual-source CT [(25.7±2.9)HU] was higher than that of third-generation dual-soure CT[(18.6±4.2)HU](t=5.24,P=0.000).The subjective image noise of second-generation dual-source CT [(4.60±0.49)scores] was significantly lower than that of third-generation dual-source CT [(4.80±0.40)scores] (t=4.15, P=0.000). Conclusion Chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT that produces high image quality and low radiation dose when using a stellar infinity detector with spectral shaping.
Key concepts: Medicine, Nuclear medicine, Image quality, Third generation, Radiation dose, Effective dose (radiation), Radiology, Image (mathematics)