2020DOAJ (DOAJ: Directory of Open Access Journals)Requires access

Point-of-care Hemoglobin Measurement in Comparison with Hematology Analyzer: A Cross-sectional Study in Emergency Department

Ali Arhami Dolatabadi, Hamidreza Hatamabadi, Kamal Amini

Open publisher page 0 citations

Abstract

\nIntroduction: Point-of-care hemoglobin testing devices can help emergency physicians to make their clinical decisions in a timelier manner. They can also improve the patient care process by decreasing the length of stay and costs. Although different devices are available now, their diagnostic accuracy remains still uncertain. Objective: This study compares the results of hemoglobin levels measured by a point-of-care hemoglobin testing device and central lab auto-analyzer. Methods: Hemoglobin level was measured both by a point-of-care device (Mission® Plus Hb) and the central laboratory auto-analyzer (Sysmex KX-21N™) in medical cases presenting to emergency department (ED) and requiring hemoglobin (Hb)/hematocrit (Hct) level measurement. The agreement of Hb and Hct between the two methods was assessed based on intraclass correlation coinfection (ICC), Bland-Altman analysis and the Mountain plots. Also, time gap between point-of-care testing and preparation of central lab results was measured. Results: Hb and Hct were measured in 86 cases mostly presented because of gastrointestinal bleeding. We found a good agreement between the two methods for hemoglobin (ICC=0.985) and hematocrit levels (ICC=0.991). The bias was 0.09 and 95% limits of agreement (LoA) were -0.89 to 1.07 for Hb level. Mean of time delay between point-of-care testing and preparation of central lab results was 207.31 minutes (SD=93.66) and this delay was clinically significant (p=0.001). Conclusion: Point-of-care measurement of Hb level provides proper quantitative results in ED patients. It significantly decreases laboratory turnaround time and may be used to improve the patient throughput by decreasing the length of stay in most clinical settings.\n

About this research paper

What this paper is about

\nIntroduction: Point-of-care hemoglobin testing devices can help emergency physicians to make their clinical decisions in a timelier manner. They can also improve the patient care process by decreasing the length of stay and costs. Although different devices are available now, their diagnostic accuracy remains still uncertain. Objective: This study compares the results of hemoglobin levels measured by a point-of-care hemoglobin testing device and central lab auto-analyzer. Methods: Hemoglobin level was measured both by a point-of-care device (Mission® Plus Hb) and the central laboratory auto-analyzer (Sysmex KX-21N™) in medical cases presenting to emergency department (ED) and requiring hemoglobin (Hb)/hematocrit (Hct) level measurement. The agreement of Hb and Hct between the two methods was assessed based on intraclass correlation coinfection (ICC), Bland-Altman analysis and the Mountain plots. Also, time gap between point-of-care testing and preparation of central lab results was measured. Results: Hb and Hct were measured in 86 cases mostly presented because of gastrointestinal bleeding. We found a good agreement between the two methods for hemoglobin (ICC=0.985) and hematocrit levels (ICC=0.991). The bias was 0.09 and 95% limits of agreement (LoA) were -0.89 to 1.07 for Hb level. Mean of time delay between point-of-care testing and preparation of central lab results was 207.31 minutes (SD=93.66) and this delay was clinically significant (p=0.001). Conclusion: Point-of-care measurement of Hb level provides proper quantitative results in ED patients. It significantly decreases laboratory turnaround time and may be used to improve the patient throughput by decreasing the length of stay in most clinical settings.\n

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

\nIntroduction: Point-of-care hemoglobin testing devices can help emergency physicians to make their clinical decisions in a timelier manner. They can also improve the patient care process by decreasing the length of stay and costs. Although different devices are available now, their diagnostic accuracy remains still uncertain. Objective: This study compares the results of hemoglobin levels measured by a point-of-care hemoglobin testing device and central lab auto-analyzer. Methods: Hemoglobin level was measured both by a point-of-care device (Mission® Plus Hb) and the central laboratory auto-analyzer (Sysmex KX-21N™) in medical cases presenting to emergency department (ED) and requiring hemoglobin (Hb)/hematocrit (Hct) level measurement. The agreement of Hb and Hct between the two methods was assessed based on intraclass correlation coinfection (ICC), Bland-Altman analysis and the Mountain plots. Also, time gap between point-of-care testing and preparation of central lab results was measured. Results: Hb and Hct were measured in 86 cases mostly presented because of gastrointestinal bleeding. We found a good agreement between the two methods for hemoglobin (ICC=0.985) and hematocrit levels (ICC=0.991). The bias was 0.09 and 95% limits of agreement (LoA) were -0.89 to 1.07 for Hb level. Mean of time delay between point-of-care testing and preparation of central lab results was 207.31 minutes (SD=93.66) and this delay was clinically significant (p=0.001). Conclusion: Point-of-care measurement of Hb level provides proper quantitative results in ED patients. It significantly decreases laboratory turnaround time and may be used to improve the patient throughput by decreasing the length of stay in most clinical settings.\n

Key concepts: Point of care, Point-of-care testing, Medicine, Emergency department, Hematocrit, Intraclass correlation, Limits of agreement, Hemoglobin

Related papers

Back to paper searchBrowse research topicsOriginal source
Point-of-care Hemoglobin Measurement in Comparison with Hematology Analyzer: A Cross-sectional Study in Emergency Department — Research Paper | ScholarLens