2019Clinical and Experimental HepatologyOpen access

The usefulness of commercially available serological tests in the diagnosis and monitoring of treatment in patients with alveolar echinococcosis

Małgorzata Sulima, Beata Szostakowska, Wacław Nahorski, Katarzyna Sikorska, Wojciech Wołyniec, Piotr Wąż

Open full text 7 citations

Abstract

AIM OF THE STUDY: To assess the clinical usefulness of serological tests in the diagnosis and monitoring of treatment of patients with alveolar echinococcosis (AE). MATERIAL AND METHODS: The results of serological tests, i.e. Echinococcus multilocularis ELISA (Bordier Affinity Products) and Echinococcus Western Blot IgG (LDBIO Diagnostic), of 66 patients were analysed. Duration of follow-up was two years after diagnosis. In the second phase of the study 11 sera obtained from the patients undergoing surgical treatment, in whom the results of Echinococcus Western Blot IgG assay were still positive, were additionally tested with Anti-Echinococcus EUROLINE-WB (IgG) assay. RESULTS: Statistically significant negativization of the Echinococcus multilocularis ELISA test was observed in the group of patients who underwent radical surgery or liver transplantation. Negativization of Echinococcus Western Blot IgG assay results was observed in some patients, among both those who received conservative treatment and those who underwent surgery, but no statistically significant differences were found between treatment groups. In 54.5% of cases the Anti-Echinococcus EUROLINE-WB (IgG) test result was negative when the results of the Echinococcus Western Blot IgG assay were still positive. CONCLUSIONS: Echinococcus multilocularis ELISA proved to be useful in assessing the activity of AE in a group of patients who underwent radical surgery or liver transplantation. The results of our study suggest that Anti-Echinococcus EUROLINE-WB (IgG) is a more dynamic test, which at the time of disappearance of AE activity becomes negative earlier.

Open-access reader

About this research paper

What this paper is about

AIM OF THE STUDY: To assess the clinical usefulness of serological tests in the diagnosis and monitoring of treatment of patients with alveolar echinococcosis (AE). MATERIAL AND METHODS: The results of serological tests, i.e. Echinococcus multilocularis ELISA (Bordier Affinity Products) and Echinococcus Western Blot IgG (LDBIO Diagnostic), of 66 patients were analysed. Duration of follow-up was two years after diagnosis. In the second phase of the study 11 sera obtained from the patients undergoing surgical treatment, in whom the results of Echinococcus Western Blot IgG assay were still positive, were additionally tested with Anti-Echinococcus EUROLINE-WB (IgG) assay. RESULTS: Statistically significant negativization of the Echinococcus multilocularis ELISA test was observed in the group of patients who underwent radical surgery or liver transplantation. Negativization of Echinococcus Western Blot IgG assay results was observed in some patients, among both those who received conservative treatment and those who underwent surgery, but no statistically significant differences were found between treatment groups. In 54.5% of cases the Anti-Echinococcus EUROLINE-WB (IgG) test result was negative when the results of the Echinococcus Western Blot IgG assay were still positive. CONCLUSIONS: Echinococcus multilocularis ELISA proved to be useful in assessing the activity of AE in a group of patients who underwent radical surgery or liver transplantation. The results of our study suggest that Anti-Echinococcus EUROLINE-WB (IgG) is a more dynamic test, which at the time of disappearance of AE activity becomes negative earlier.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM OF THE STUDY: To assess the clinical usefulness of serological tests in the diagnosis and monitoring of treatment of patients with alveolar echinococcosis (AE). MATERIAL AND METHODS: The results of serological tests, i.e. Echinococcus multilocularis ELISA (Bordier Affinity Products) and Echinococcus Western Blot IgG (LDBIO Diagnostic), of 66 patients were analysed. Duration of follow-up was two years after diagnosis. In the second phase of the study 11 sera obtained from the patients undergoing surgical treatment, in whom the results of Echinococcus Western Blot IgG assay were still positive, were additionally tested with Anti-Echinococcus EUROLINE-WB (IgG) assay. RESULTS: Statistically significant negativization of the Echinococcus multilocularis ELISA test was observed in the group of patients who underwent radical surgery or liver transplantation. Negativization of Echinococcus Western Blot IgG assay results was observed in some patients, among both those who received conservative treatment and those who underwent surgery, but no statistically significant differences were found between treatment groups. In 54.5% of cases the Anti-Echinococcus EUROLINE-WB (IgG) test result was negative when the results of the Echinococcus Western Blot IgG assay were still positive. CONCLUSIONS: Echinococcus multilocularis ELISA proved to be useful in assessing the activity of AE in a group of patients who underwent radical surgery or liver transplantation. The results of our study suggest that Anti-Echinococcus EUROLINE-WB (IgG) is a more dynamic test, which at the time of disappearance of AE activity becomes negative earlier.

Key concepts: Alveolar echinococcosis, Serology, Medicine, Echinococcosis, Intensive care medicine, Pathology, Immunology, Antibody

Related papers

Back to paper searchBrowse research topicsOriginal source
The usefulness of commercially available serological tests in the diagnosis and monitoring of treatment in patients with alveolar echinococcosis — Research Paper | ScholarLens