2018PubMedOpen access

[Occlusal analysis of implant-supported fixed denture in edentulous patients].

Xiaoqian Li, Xiaoni Ma, Xin Xu

Open full text 5 citations

Abstract

OBJECTIVE: This study aims to evaluate the occlusal characteristics of full edentulous patients with implant-supported prostheses and to provide a reference with the occlusal situation for clinicians. METHODS: A Teetester occlusal analysis system was used with 30 full edentulous patients of implant-supported fixed denture (test group) in comparison with 30 natural dentition (control group). The percentage of occlusal force distribution were measured, as well as the occlusal time at the intercuspal, protrusion, and left and right lateral positions. RESULTS: Compared with control group, the occlusion time, maximum occlusal force in intercuspal of test group significantly reduced (P<0.05); while control group was obviously superior to test group in the left and right bit force degree. Disclusion time in protrusion, occlusion times in lateral positions of test group also significantly reduced (P<0.05). There were no significant differences in average occlusion force, percentage of total force in anterior teeth, and lateral occlusion between test group and control group. CONCLUSIONS: The maximum occlusal force in intercuspal of full edentulous patients with implant-supported prostheses reduce. The occlusal force in protrusive occlusion is concentrated in the front teeth, and the group function occlusion is the main lateral occlusal pattern.

About this research paper

What this paper is about

OBJECTIVE: This study aims to evaluate the occlusal characteristics of full edentulous patients with implant-supported prostheses and to provide a reference with the occlusal situation for clinicians. METHODS: A Teetester occlusal analysis system was used with 30 full edentulous patients of implant-supported fixed denture (test group) in comparison with 30 natural dentition (control group). The percentage of occlusal force distribution were measured, as well as the occlusal time at the intercuspal, protrusion, and left and right lateral positions. RESULTS: Compared with control group, the occlusion time, maximum occlusal force in intercuspal of test group significantly reduced (P<0.05); while control group was obviously superior to test group in the left and right bit force degree. Disclusion time in protrusion, occlusion times in lateral positions of test group also significantly reduced (P<0.05). There were no significant differences in average occlusion force, percentage of total force in anterior teeth, and lateral occlusion between test group and control group. CONCLUSIONS: The maximum occlusal force in intercuspal of full edentulous patients with implant-supported prostheses reduce. The occlusal force in protrusive occlusion is concentrated in the front teeth, and the group function occlusion is the main lateral occlusal pattern.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: This study aims to evaluate the occlusal characteristics of full edentulous patients with implant-supported prostheses and to provide a reference with the occlusal situation for clinicians. METHODS: A Teetester occlusal analysis system was used with 30 full edentulous patients of implant-supported fixed denture (test group) in comparison with 30 natural dentition (control group). The percentage of occlusal force distribution were measured, as well as the occlusal time at the intercuspal, protrusion, and left and right lateral positions. RESULTS: Compared with control group, the occlusion time, maximum occlusal force in intercuspal of test group significantly reduced (P<0.05); while control group was obviously superior to test group in the left and right bit force degree. Disclusion time in protrusion, occlusion times in lateral positions of test group also significantly reduced (P<0.05). There were no significant differences in average occlusion force, percentage of total force in anterior teeth, and lateral occlusion between test group and control group. CONCLUSIONS: The maximum occlusal force in intercuspal of full edentulous patients with implant-supported prostheses reduce. The occlusal force in protrusive occlusion is concentrated in the front teeth, and the group function occlusion is the main lateral occlusal pattern.

Key concepts: Occlusion, Dentistry, Bite force quotient, Medicine, Implant, Orthodontics, Dental occlusion, Dentition

Related papers

Back to paper searchBrowse research topicsOriginal source
[Occlusal analysis of implant-supported fixed denture in edentulous patients]. — Research Paper | ScholarLens