2019Unpublished venueRequires access

Optimization of Entering Path for Equipotential Live Work on ± 800 kV UHV DC Line

Yadi Zhang, Wencheng Sun, Ke Yang, Zehua Huang, Yuanjie Jiang

Open publisher page 0 citations

Abstract

Equipotential operation is the main way of live operation for ±800 kV UHV DC lines. In this paper, the numerical simulation method is used to study the optimum path to enter the equipotential in live operation of ±800 kV UHV DC lines. Firstly, according to the actual situation of live operation of typical straight-line towers in ±800 kV DC lines, a simulation model is established in the finite element analysis software ANSYS. Then, the dynamic distribution of electric field intensity on the human body surface is calculated when the operator enters the equipotential process along all possible paths and is located at several different points. The results show that the maximum electric field intensity of human body surface is different when it enters the equipotential along different paths, and the difference of the maximum electric field intensity between different paths can reach 1.7 times. The most reasonable entry path is from the tower level.

About this research paper

What this paper is about

Equipotential operation is the main way of live operation for ±800 kV UHV DC lines. In this paper, the numerical simulation method is used to study the optimum path to enter the equipotential in live operation of ±800 kV UHV DC lines. Firstly, according to the actual situation of live operation of typical straight-line towers in ±800 kV DC lines, a simulation model is established in the finite element analysis software ANSYS. Then, the dynamic distribution of electric field intensity on the human body surface is calculated when the operator enters the equipotential process along all possible paths and is located at several different points. The results show that the maximum electric field intensity of human body surface is different when it enters the equipotential along different paths, and the difference of the maximum electric field intensity between different paths can reach 1.7 times. The most reasonable entry path is from the tower level.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Equipotential operation is the main way of live operation for ±800 kV UHV DC lines. In this paper, the numerical simulation method is used to study the optimum path to enter the equipotential in live operation of ±800 kV UHV DC lines. Firstly, according to the actual situation of live operation of typical straight-line towers in ±800 kV DC lines, a simulation model is established in the finite element analysis software ANSYS. Then, the dynamic distribution of electric field intensity on the human body surface is calculated when the operator enters the equipotential process along all possible paths and is located at several different points. The results show that the maximum electric field intensity of human body surface is different when it enters the equipotential along different paths, and the difference of the maximum electric field intensity between different paths can reach 1.7 times. The most reasonable entry path is from the tower level.

Key concepts: Equipotential, Electric field, Equipotential surface, Line (geometry), Path (computing), Electrical engineering, Tower, Intensity (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of Entering Path for Equipotential Live Work on ± 800 kV UHV DC Line — Research Paper | ScholarLens