2018•PubMedOpen access

[Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate].

Depeng Meng, Yueping Ouyang, Huihao Chen, Jun Mei Zhou, Zheng Xie, Yaofa Lin, Haodong Lin, Chunlin Hou

Open full text 0 citations

Abstract

Objective: To compare the biomechanical difference between petal-shaped poly-axial locking plate and tension band wire cerclage in fixing star-shaped 6-part patellar fractures in cadaver model, and provide the experimental data for clinical use. Methods: The paired 12 knee specimens from 6 human cadavers were randomly divided into 2 groups (the control group and the test group) after a star-shaped 6-part patellar fracture model was established. The specimens were weighted, and the control group was fixed with tension band wire cerclage and the test group was fixed with petal-shaped poly-axial locking plate. The specimens were connected to CMT5105 biomechanics test machine by a customized fixture, the total fracture gap of patellar fracture blocks was measured before testing. The knee extensor load test was performed to record the extensor load of knees at 90° flexion to extension. Then the anti gravity physiological knee extension process at 90° flexion was stimulated according to the knee extensor load. The cyclic times until failure and the total fracture gap of patellar fracture blocks after failure were recorded. Results: =0.046). The failure reasons in control group were all the wires slipped off the Kirschner wires, while the failure reasons in test group were the screws pulled out from the upper pole in 5 cases (83.3%) and from the lower pole in 1 case (16.7%). Conclusion: The petal-shaped poly-axial locking plate has better biomechanical stiffness to fix the star-shaped 6-part patellar fractures when compared with tension band wire cerclage method. However, this type of fracture is a serious comminuted type, and the early excessive activity still carries the risk of displacement.

About this research paper

What this paper is about

Objective: To compare the biomechanical difference between petal-shaped poly-axial locking plate and tension band wire cerclage in fixing star-shaped 6-part patellar fractures in cadaver model, and provide the experimental data for clinical use. Methods: The paired 12 knee specimens from 6 human cadavers were randomly divided into 2 groups (the control group and the test group) after a star-shaped 6-part patellar fracture model was established. The specimens were weighted, and the control group was fixed with tension band wire cerclage and the test group was fixed with petal-shaped poly-axial locking plate. The specimens were connected to CMT5105 biomechanics test machine by a customized fixture, the total fracture gap of patellar fracture blocks was measured before testing. The knee extensor load test was performed to record the extensor load of knees at 90° flexion to extension. Then the anti gravity physiological knee extension process at 90° flexion was stimulated according to the knee extensor load. The cyclic times until failure and the total fracture gap of patellar fracture blocks after failure were recorded. Results: =0.046). The failure reasons in control group were all the wires slipped off the Kirschner wires, while the failure reasons in test group were the screws pulled out from the upper pole in 5 cases (83.3%) and from the lower pole in 1 case (16.7%). Conclusion: The petal-shaped poly-axial locking plate has better biomechanical stiffness to fix the star-shaped 6-part patellar fractures when compared with tension band wire cerclage method. However, this type of fracture is a serious comminuted type, and the early excessive activity still carries the risk of displacement.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To compare the biomechanical difference between petal-shaped poly-axial locking plate and tension band wire cerclage in fixing star-shaped 6-part patellar fractures in cadaver model, and provide the experimental data for clinical use. Methods: The paired 12 knee specimens from 6 human cadavers were randomly divided into 2 groups (the control group and the test group) after a star-shaped 6-part patellar fracture model was established. The specimens were weighted, and the control group was fixed with tension band wire cerclage and the test group was fixed with petal-shaped poly-axial locking plate. The specimens were connected to CMT5105 biomechanics test machine by a customized fixture, the total fracture gap of patellar fracture blocks was measured before testing. The knee extensor load test was performed to record the extensor load of knees at 90° flexion to extension. Then the anti gravity physiological knee extension process at 90° flexion was stimulated according to the knee extensor load. The cyclic times until failure and the total fracture gap of patellar fracture blocks after failure were recorded. Results: =0.046). The failure reasons in control group were all the wires slipped off the Kirschner wires, while the failure reasons in test group were the screws pulled out from the upper pole in 5 cases (83.3%) and from the lower pole in 1 case (16.7%). Conclusion: The petal-shaped poly-axial locking plate has better biomechanical stiffness to fix the star-shaped 6-part patellar fractures when compared with tension band wire cerclage method. However, this type of fracture is a serious comminuted type, and the early excessive activity still carries the risk of displacement.

Key concepts: Patella fracture, Biomechanics, Orthodontics, Cadaver, Fixation (population genetics), Medicine, Tension band wiring, Fracture (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
[Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate]. — Research Paper | ScholarLens