The plasma parameters and neutron yield at device of "Plasma focus"
А. М. Жукешов, Zh. M. Мoldabekov, A. Ioffe
Abstract
Open-access reader
А. М. Жукешов, Zh. M. Мoldabekov, A. Ioffe
Abstract
Open-access reader
Present work presents calculations and experimental studies on the formation and dynamics of plasma onthe “plasma focus” set up. Physical conditions were determined and critical parameters were calculatedfor estimating the neutron yield for kilojoule and megajoule set ups. The results of plasma diagnostics andflow formation in the CPA-30 and PF-4 set ups are also shown. A comparison of calculated data andexperimental values is performed. The value of the neutron yield parameter is justified and the possiblecause of the appearance of saturation is indicated. The rationale for the development of further research inthe direction of creating conditions for thermonuclear fusion in installations of the plasma focus type isgiven. The neutron flux was observed on high-voltage gas discharges with a specific geometry of theelectrodes. The result of measuring the anisotropy of the neutron yield along the axial z and radial φdirections was equal to Yn(z)/Yn(φ)~ 2 ÷ 3, which contradicts the thermonuclear mechanism.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Present work presents calculations and experimental studies on the formation and dynamics of plasma onthe “plasma focus” set up. Physical conditions were determined and critical parameters were calculatedfor estimating the neutron yield for kilojoule and megajoule set ups. The results of plasma diagnostics andflow formation in the CPA-30 and PF-4 set ups are also shown. A comparison of calculated data andexperimental values is performed. The value of the neutron yield parameter is justified and the possiblecause of the appearance of saturation is indicated. The rationale for the development of further research inthe direction of creating conditions for thermonuclear fusion in installations of the plasma focus type isgiven. The neutron flux was observed on high-voltage gas discharges with a specific geometry of theelectrodes. The result of measuring the anisotropy of the neutron yield along the axial z and radial φdirections was equal to Yn(z)/Yn(φ)~ 2 ÷ 3, which contradicts the thermonuclear mechanism.
Key concepts: Thermonuclear fusion, Dense plasma focus, Neutron, Plasma, Yield (engineering), Neutron flux, Anisotropy, Nuclear fusion