2019•Physiological MeasurementOpen access

Finger and forehead PPG signal comparison for respiratory rate estimation

Alberto Hernando, María Dolores Peláez‐Coca, M.T. Lozano, Jesús Mateo Lázaro, Eduardo Gil

Open full text 26 citations

Abstract

OBJECTIVE: An evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. APPROACH: Finger PPG, forehead PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG-derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability, pulse amplitude variability and the respiratory-induced intensity variability (RIIV). Respiratory rate was estimated from each one of the four PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. MAIN RESULTS: Results show better performance in terms of successful estimation and relative error when: (i) PPG signal is recorded in the finger; (ii) the respiratory rate is less than 0.4 Hz; (iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. SIGNIFICANCE: These results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that the finger is better than the forehead to estimate respiratory rate.

Open-access reader

About this research paper

What this paper is about

OBJECTIVE: An evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. APPROACH: Finger PPG, forehead PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG-derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability, pulse amplitude variability and the respiratory-induced intensity variability (RIIV). Respiratory rate was estimated from each one of the four PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. MAIN RESULTS: Results show better performance in terms of successful estimation and relative error when: (i) PPG signal is recorded in the finger; (ii) the respiratory rate is less than 0.4 Hz; (iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. SIGNIFICANCE: These results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that the finger is better than the forehead to estimate respiratory rate.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: An evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. APPROACH: Finger PPG, forehead PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG-derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability, pulse amplitude variability and the respiratory-induced intensity variability (RIIV). Respiratory rate was estimated from each one of the four PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. MAIN RESULTS: Results show better performance in terms of successful estimation and relative error when: (i) PPG signal is recorded in the finger; (ii) the respiratory rate is less than 0.4 Hz; (iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. SIGNIFICANCE: These results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that the finger is better than the forehead to estimate respiratory rate.

Key concepts: Photoplethysmogram, Respiratory rate, Forehead, Respiratory system, SIGNAL (programming language), Pulse (music), Biomedical engineering, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Finger and forehead PPG signal comparison for respiratory rate estimation — Research Paper | ScholarLens