2019Hip InternationalRequires access

Influence of pelvic sagittal tilt on 3-dimensional bone coverage in total hip arthroplasty: a simulation analysis

Takuro Ueno, Tamon Kabata, Yoshitomo Kajino, Tomoharu Takagi, Takaaki Ohmori, Junya Yoshitani, Hiroyuki Tsuchiya

Open publisher page 1 citations

Abstract

Background: In total hip arthroplasty with computer navigation assistance, cup orientation is generally determined according to the coordinate system relative to the functional pelvic plane (FPP). However, there is a large difference in the cup anteversion between a posterior pelvic tilt relative to the computed tomography (CT) table in the sagittal plane and anterior pelvic tilt, even when the cup is set at the same orientation angle according to each FPP. The present study analysed this difference from the viewpoint of 3-dimensional (3D) coverage of the acetabular component (3D coverage) to determine how the 3D acetabular coverage is altered with changes in pelvic sagittal tilt. Methods: We analysed 3D-simulated acetabular coverage measured in 3D pelvic models reconstructed from the preoperative CT data of 50 patients. In each patient, we created 5 pelvic models with a sagittal tilt of 10° increments between 20° anterior tilt and 20° posterior tilt relative to the CT table. Results: We found that 3D coverage decreased as the pelvis tilted posteriorly. Particularly, there were significant differences between the pelvis with 20° anterior tilt and that with neutral tilt ( p < 0.001). There was also a difference between the pelvis with neutral tilt and that with a 20° posterior tilt ( p < 0.01). The mean decrease in 3D coverage between the pelvis with neutral tilt and that with 20° posterior tilt was 7.2 ± 1.6%. Conclusions: We found that 3D coverage differed among pelvis with different sagittal tilts when the cup orientation angle was determined according to FPP.

About this research paper

What this paper is about

Background: In total hip arthroplasty with computer navigation assistance, cup orientation is generally determined according to the coordinate system relative to the functional pelvic plane (FPP). However, there is a large difference in the cup anteversion between a posterior pelvic tilt relative to the computed tomography (CT) table in the sagittal plane and anterior pelvic tilt, even when the cup is set at the same orientation angle according to each FPP. The present study analysed this difference from the viewpoint of 3-dimensional (3D) coverage of the acetabular component (3D coverage) to determine how the 3D acetabular coverage is altered with changes in pelvic sagittal tilt. Methods: We analysed 3D-simulated acetabular coverage measured in 3D pelvic models reconstructed from the preoperative CT data of 50 patients. In each patient, we created 5 pelvic models with a sagittal tilt of 10° increments between 20° anterior tilt and 20° posterior tilt relative to the CT table. Results: We found that 3D coverage decreased as the pelvis tilted posteriorly. Particularly, there were significant differences between the pelvis with 20° anterior tilt and that with neutral tilt ( p < 0.001). There was also a difference between the pelvis with neutral tilt and that with a 20° posterior tilt ( p < 0.01). The mean decrease in 3D coverage between the pelvis with neutral tilt and that with 20° posterior tilt was 7.2 ± 1.6%. Conclusions: We found that 3D coverage differed among pelvis with different sagittal tilts when the cup orientation angle was determined according to FPP.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: In total hip arthroplasty with computer navigation assistance, cup orientation is generally determined according to the coordinate system relative to the functional pelvic plane (FPP). However, there is a large difference in the cup anteversion between a posterior pelvic tilt relative to the computed tomography (CT) table in the sagittal plane and anterior pelvic tilt, even when the cup is set at the same orientation angle according to each FPP. The present study analysed this difference from the viewpoint of 3-dimensional (3D) coverage of the acetabular component (3D coverage) to determine how the 3D acetabular coverage is altered with changes in pelvic sagittal tilt. Methods: We analysed 3D-simulated acetabular coverage measured in 3D pelvic models reconstructed from the preoperative CT data of 50 patients. In each patient, we created 5 pelvic models with a sagittal tilt of 10° increments between 20° anterior tilt and 20° posterior tilt relative to the CT table. Results: We found that 3D coverage decreased as the pelvis tilted posteriorly. Particularly, there were significant differences between the pelvis with 20° anterior tilt and that with neutral tilt ( p < 0.001). There was also a difference between the pelvis with neutral tilt and that with a 20° posterior tilt ( p < 0.01). The mean decrease in 3D coverage between the pelvis with neutral tilt and that with 20° posterior tilt was 7.2 ± 1.6%. Conclusions: We found that 3D coverage differed among pelvis with different sagittal tilts when the cup orientation angle was determined according to FPP.

Key concepts: Medicine, Pelvic tilt, Total hip arthroplasty, Sagittal plane, Arthroplasty, Orthodontics, Tilt (camera), Hip arthroplasty

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of pelvic sagittal tilt on 3-dimensional bone coverage in total hip arthroplasty: a simulation analysis — Research Paper | ScholarLens