1993•Transactions of the American Nuclear SocietyRequires access

Containment failure time and mode for a low-pressure short-term station blackout in a BWR-4 with Mark-I containment

Juan J. Carbajo, Sherrell R. Greene

Open publisher page 2 citations

Abstract

This study investigates containment failure time and mode for a low-pressure, short-term station blackout severe accident sequence in a boiling water reactor (BWR-4) with a Mark-I containment. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Other results using the MELCOR/CORBH package and the BWRSAR and CONTAIN codes are also presented and compared to the MELCOR results. The plant analyzed is the Peach Bottom atomic station, a BWR-4 with a Mark-I containment. The automatic depressurization system was used to depressurize the vessel in accordance with the Emergency Procedure Guidelines. Two different variations of the station blackout were studied: one with a dry cavity and the other with a flooded cavity. For the flooded cavity, it is assumed that a control rod drive (CRD) pump becomes operational after vessel failure, and it is used to pump water into the cavity.

About this research paper

What this paper is about

This study investigates containment failure time and mode for a low-pressure, short-term station blackout severe accident sequence in a boiling water reactor (BWR-4) with a Mark-I containment. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Other results using the MELCOR/CORBH package and the BWRSAR and CONTAIN codes are also presented and compared to the MELCOR results. The plant analyzed is the Peach Bottom atomic station, a BWR-4 with a Mark-I containment. The automatic depressurization system was used to depressurize the vessel in accordance with the Emergency Procedure Guidelines. Two different variations of the station blackout were studied: one with a dry cavity and the other with a flooded cavity. For the flooded cavity, it is assumed that a control rod drive (CRD) pump becomes operational after vessel failure, and it is used to pump water into the cavity.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study investigates containment failure time and mode for a low-pressure, short-term station blackout severe accident sequence in a boiling water reactor (BWR-4) with a Mark-I containment. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Other results using the MELCOR/CORBH package and the BWRSAR and CONTAIN codes are also presented and compared to the MELCOR results. The plant analyzed is the Peach Bottom atomic station, a BWR-4 with a Mark-I containment. The automatic depressurization system was used to depressurize the vessel in accordance with the Emergency Procedure Guidelines. Two different variations of the station blackout were studied: one with a dry cavity and the other with a flooded cavity. For the flooded cavity, it is assumed that a control rod drive (CRD) pump becomes operational after vessel failure, and it is used to pump water into the cavity.

Key concepts: Blackout, Containment (computer programming), Nuclear engineering, Cabin pressurization, Boiling water reactor, Environmental science, Accident management, Corium

Related papers

Back to paper searchBrowse research topicsOriginal source
Containment failure time and mode for a low-pressure short-term station blackout in a BWR-4 with Mark-I containment — Research Paper | ScholarLens