Containment failure time and mode for a low-pressure short-term station blackout in a BWR-4 with Mark-I containment
Juan J. Carbajo, Sherrell R. Greene
Abstract
Juan J. Carbajo, Sherrell R. Greene
Abstract
This study investigates containment failure time and mode for a low-pressure, short-term station blackout severe accident sequence in a boiling water reactor (BWR-4) with a Mark-I containment. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Other results using the MELCOR/CORBH package and the BWRSAR and CONTAIN codes are also presented and compared to the MELCOR results. The plant analyzed is the Peach Bottom atomic station, a BWR-4 with a Mark-I containment. The automatic depressurization system was used to depressurize the vessel in accordance with the Emergency Procedure Guidelines. Two different variations of the station blackout were studied: one with a dry cavity and the other with a flooded cavity. For the flooded cavity, it is assumed that a control rod drive (CRD) pump becomes operational after vessel failure, and it is used to pump water into the cavity.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study investigates containment failure time and mode for a low-pressure, short-term station blackout severe accident sequence in a boiling water reactor (BWR-4) with a Mark-I containment. The severe accident analysis code MELCOR, version 1.8.1, was used in these calculations. Other results using the MELCOR/CORBH package and the BWRSAR and CONTAIN codes are also presented and compared to the MELCOR results. The plant analyzed is the Peach Bottom atomic station, a BWR-4 with a Mark-I containment. The automatic depressurization system was used to depressurize the vessel in accordance with the Emergency Procedure Guidelines. Two different variations of the station blackout were studied: one with a dry cavity and the other with a flooded cavity. For the flooded cavity, it is assumed that a control rod drive (CRD) pump becomes operational after vessel failure, and it is used to pump water into the cavity.
Key concepts: Blackout, Containment (computer programming), Nuclear engineering, Cabin pressurization, Boiling water reactor, Environmental science, Accident management, Corium