2018Unpublished venueRequires access

Condition Assessment of a Gas Insulated Substation

Kittinan Witchawut, Phanupong Fuangpian, Thanapong Suwanasri, Cattareeya Suwanasri

Open publisher page 6 citations

Abstract

This paper presents condition assessment of asset in HV gas insulated substation for maintenance management in industrial area. The scoring and weighting techniques are applied for condition assessment. The component of HV substation such as circuit breaker, disconnecting switch, earthing switch, high speed earthing switch, current transformer, voltage transformer and local control panel are evaluated. The 5 bays of a 115 kV GIS substation in industrial area are evaluated as example in the assessment program. The results show the health index of components, health index of bay and health index of substation in form of percentage. The known health index of substation and its component is useful information to manage the maintenance activity with the associated cost and to plan the effective maintenance scheduling for HV substation.

About this research paper

What this paper is about

This paper presents condition assessment of asset in HV gas insulated substation for maintenance management in industrial area. The scoring and weighting techniques are applied for condition assessment. The component of HV substation such as circuit breaker, disconnecting switch, earthing switch, high speed earthing switch, current transformer, voltage transformer and local control panel are evaluated. The 5 bays of a 115 kV GIS substation in industrial area are evaluated as example in the assessment program. The results show the health index of components, health index of bay and health index of substation in form of percentage. The known health index of substation and its component is useful information to manage the maintenance activity with the associated cost and to plan the effective maintenance scheduling for HV substation.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents condition assessment of asset in HV gas insulated substation for maintenance management in industrial area. The scoring and weighting techniques are applied for condition assessment. The component of HV substation such as circuit breaker, disconnecting switch, earthing switch, high speed earthing switch, current transformer, voltage transformer and local control panel are evaluated. The 5 bays of a 115 kV GIS substation in industrial area are evaluated as example in the assessment program. The results show the health index of components, health index of bay and health index of substation in form of percentage. The known health index of substation and its component is useful information to manage the maintenance activity with the associated cost and to plan the effective maintenance scheduling for HV substation.

Key concepts: Transformer, Circuit breaker, Ground, Reliability engineering, Asset management, Engineering, Maintenance engineering, Health assessment