2018International Journal of Advances in Engineering and Pure SciencesOpen access

Determination of Chlorpyrifos Residues in Cherry Samples by Direct Immersion Solid Phase Microextraction Coupled with Gas Chromatography Mass Spectrometry

Oya Aydın Urucu, Ece Kök Yetimoğlu, Deniz Devecioğlu

Open full text 0 citations

Abstract

A method based on a solid phase microextraction gas chromatography- mass spectrometry (SPME-GC/MS) was developed for the quantitative determination of chlorpyrifos residues in cherry samples. Three kinds of fiber coatings: PA (polyacrylate, 85µm), PDMS–DVB (polydimethylsiloxane–divinylbenzene 65 mm) and PDMS (polydimethylsiloxane, 100 mm) were compared. Various parameters affecting SPME procedures such as temperature, extraction and desorption times, salinity, stirring rate were investigated. The analytes from all sample extracts were preconcentrated for 30 minutes in the SPME fiber at 60 °C and then the fiber was desorbed by heating at 250 °C for 10 minutes in the gas chromatography injection port. Limits of detection (LOD) and quantitation (LOQ) values were 0.03 µg/L and 0,1 µg/L, respectively. An average recovery range was 93-98% with relative standard deviation (RSD) < 10 %.

Open-access reader

About this research paper

What this paper is about

A method based on a solid phase microextraction gas chromatography- mass spectrometry (SPME-GC/MS) was developed for the quantitative determination of chlorpyrifos residues in cherry samples. Three kinds of fiber coatings: PA (polyacrylate, 85µm), PDMS–DVB (polydimethylsiloxane–divinylbenzene 65 mm) and PDMS (polydimethylsiloxane, 100 mm) were compared. Various parameters affecting SPME procedures such as temperature, extraction and desorption times, salinity, stirring rate were investigated. The analytes from all sample extracts were preconcentrated for 30 minutes in the SPME fiber at 60 °C and then the fiber was desorbed by heating at 250 °C for 10 minutes in the gas chromatography injection port. Limits of detection (LOD) and quantitation (LOQ) values were 0.03 µg/L and 0,1 µg/L, respectively. An average recovery range was 93-98% with relative standard deviation (RSD) < 10 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method based on a solid phase microextraction gas chromatography- mass spectrometry (SPME-GC/MS) was developed for the quantitative determination of chlorpyrifos residues in cherry samples. Three kinds of fiber coatings: PA (polyacrylate, 85µm), PDMS–DVB (polydimethylsiloxane–divinylbenzene 65 mm) and PDMS (polydimethylsiloxane, 100 mm) were compared. Various parameters affecting SPME procedures such as temperature, extraction and desorption times, salinity, stirring rate were investigated. The analytes from all sample extracts were preconcentrated for 30 minutes in the SPME fiber at 60 °C and then the fiber was desorbed by heating at 250 °C for 10 minutes in the gas chromatography injection port. Limits of detection (LOD) and quantitation (LOQ) values were 0.03 µg/L and 0,1 µg/L, respectively. An average recovery range was 93-98% with relative standard deviation (RSD) < 10 %.

Key concepts: Solid-phase microextraction, Chromatography, Chemistry, Mass spectrometry, Polydimethylsiloxane, Gas chromatography, Gas chromatography–mass spectrometry, Divinylbenzene

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorpyrifos Residues in Cherry Samples by Direct Immersion Solid Phase Microextraction Coupled with Gas Chromatography Mass Spectrometry — Research Paper | ScholarLens