2018Unpublished venueRequires access

Diagnosis and Analysis of Wall Bushing Typical Partial Discharge Fault in Switchgear

Zhixiang Liu, Yongxiang Li, Zhenyu Zhang, Liqiang Ma, Qingsong Chen

Open publisher page 2 citations

Abstract

There are many reasons for the partial discharge in switchgear, so to achieve the safety and reliability operation of switchgear is more important. The internal partial discharge of wall bushing in switchgear are researched by employing the transient earth voltage detection method, ultrasonic detection method and ultra high frequency detection method based on the partial discharge case. Based on the related testing data, the amplitude, type and reason of partial discharge are discussed, and the location of partial discharge are accomplished by using the method of the acoustic-electric location method. The signal of partial discharge of wall bushing disappears after the treatment. The study shows that it can provide a reference basis for the practical measurement and accurate location for the internal partial discharge fault of wall bushing in the switchgear.

About this research paper

What this paper is about

There are many reasons for the partial discharge in switchgear, so to achieve the safety and reliability operation of switchgear is more important. The internal partial discharge of wall bushing in switchgear are researched by employing the transient earth voltage detection method, ultrasonic detection method and ultra high frequency detection method based on the partial discharge case. Based on the related testing data, the amplitude, type and reason of partial discharge are discussed, and the location of partial discharge are accomplished by using the method of the acoustic-electric location method. The signal of partial discharge of wall bushing disappears after the treatment. The study shows that it can provide a reference basis for the practical measurement and accurate location for the internal partial discharge fault of wall bushing in the switchgear.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There are many reasons for the partial discharge in switchgear, so to achieve the safety and reliability operation of switchgear is more important. The internal partial discharge of wall bushing in switchgear are researched by employing the transient earth voltage detection method, ultrasonic detection method and ultra high frequency detection method based on the partial discharge case. Based on the related testing data, the amplitude, type and reason of partial discharge are discussed, and the location of partial discharge are accomplished by using the method of the acoustic-electric location method. The signal of partial discharge of wall bushing disappears after the treatment. The study shows that it can provide a reference basis for the practical measurement and accurate location for the internal partial discharge fault of wall bushing in the switchgear.

Key concepts: Partial discharge, Switchgear, Bushing, Fault (geology), Voltage, SIGNAL (programming language), Engineering, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnosis and Analysis of Wall Bushing Typical Partial Discharge Fault in Switchgear — Research Paper | ScholarLens