2018Unpublished venueRequires access

Peak-flow or portable spirometry as a replacement for Spirometry in the diagnosis of COPD and Asthma

Sanjeev U Nair, Arjun Padmanabhan, Anitha Kumari

Open publisher page 3 citations

Abstract

Introduction: The diagnosis of Asthma and COPD at Primary care level in India is limited by lack of access to spirometry. Aims and Objectives: To determine the correlation of Peak flow recording and lung volumes on a portable mini-spirometer with the lung volumes measured by spirometry in patients with COPD and Asthma. Methods: A hospital based cross-sectional study was done at 2 tertiary care hospitals among patients diagnosed as COPD or Asthma based on a pre-&post-bronchodilator spirometry. A trained health worker performed performed measurements using a peak flow meter (Breath-O-meter®) as well as a mini-spirometer (COPD6®). The FEV1 / FVC values by spirometry were correlated with the values of peak flow and with the FEV1/FEV6 measured by the mini-spirometer. The sensitivity and specificity of the mini-spirometer (FEV1/FEV6 <70%) and the peak-flow-meter (predicted PEFR <80%) in diagnosing airflow limitation was determined with the full spirometry (FEV1/FVC <70%) as a gold standard Results: 148 patients with obstructive airway disease were included. There was poor correlation for the PEFR with the FEV1/FVC on spirometry and for the FEV1/FEV6 or the FEV1 measured on a portable mini-spirometry with the FEV1/FVC or the FEV1 respectively on spirometry. A cut-off of <80% of predicted PERF to determine obstruction had a sensitivity of 88% and specificity of 49% (Gold standard-FEV1/FVC <70% on spirometry). A cut-off of 70% of FEV1/FEV6 on the mini-spirometry for determining obstruction had a sensitivity of 64% and specificity of 96% Conclusions: Our study findings suggest that PEFR may be a good screening tool, whereas the mini-spirometer may be used as a diagnostic test in resource limted settings

About this research paper

What this paper is about

Introduction: The diagnosis of Asthma and COPD at Primary care level in India is limited by lack of access to spirometry. Aims and Objectives: To determine the correlation of Peak flow recording and lung volumes on a portable mini-spirometer with the lung volumes measured by spirometry in patients with COPD and Asthma. Methods: A hospital based cross-sectional study was done at 2 tertiary care hospitals among patients diagnosed as COPD or Asthma based on a pre-&post-bronchodilator spirometry. A trained health worker performed performed measurements using a peak flow meter (Breath-O-meter®) as well as a mini-spirometer (COPD6®). The FEV1 / FVC values by spirometry were correlated with the values of peak flow and with the FEV1/FEV6 measured by the mini-spirometer. The sensitivity and specificity of the mini-spirometer (FEV1/FEV6 <70%) and the peak-flow-meter (predicted PEFR <80%) in diagnosing airflow limitation was determined with the full spirometry (FEV1/FVC <70%) as a gold standard Results: 148 patients with obstructive airway disease were included. There was poor correlation for the PEFR with the FEV1/FVC on spirometry and for the FEV1/FEV6 or the FEV1 measured on a portable mini-spirometry with the FEV1/FVC or the FEV1 respectively on spirometry. A cut-off of <80% of predicted PERF to determine obstruction had a sensitivity of 88% and specificity of 49% (Gold standard-FEV1/FVC <70% on spirometry). A cut-off of 70% of FEV1/FEV6 on the mini-spirometry for determining obstruction had a sensitivity of 64% and specificity of 96% Conclusions: Our study findings suggest that PEFR may be a good screening tool, whereas the mini-spirometer may be used as a diagnostic test in resource limted settings

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: The diagnosis of Asthma and COPD at Primary care level in India is limited by lack of access to spirometry. Aims and Objectives: To determine the correlation of Peak flow recording and lung volumes on a portable mini-spirometer with the lung volumes measured by spirometry in patients with COPD and Asthma. Methods: A hospital based cross-sectional study was done at 2 tertiary care hospitals among patients diagnosed as COPD or Asthma based on a pre-&post-bronchodilator spirometry. A trained health worker performed performed measurements using a peak flow meter (Breath-O-meter®) as well as a mini-spirometer (COPD6®). The FEV1 / FVC values by spirometry were correlated with the values of peak flow and with the FEV1/FEV6 measured by the mini-spirometer. The sensitivity and specificity of the mini-spirometer (FEV1/FEV6 <70%) and the peak-flow-meter (predicted PEFR <80%) in diagnosing airflow limitation was determined with the full spirometry (FEV1/FVC <70%) as a gold standard Results: 148 patients with obstructive airway disease were included. There was poor correlation for the PEFR with the FEV1/FVC on spirometry and for the FEV1/FEV6 or the FEV1 measured on a portable mini-spirometry with the FEV1/FVC or the FEV1 respectively on spirometry. A cut-off of <80% of predicted PERF to determine obstruction had a sensitivity of 88% and specificity of 49% (Gold standard-FEV1/FVC <70% on spirometry). A cut-off of 70% of FEV1/FEV6 on the mini-spirometry for determining obstruction had a sensitivity of 64% and specificity of 96% Conclusions: Our study findings suggest that PEFR may be a good screening tool, whereas the mini-spirometer may be used as a diagnostic test in resource limted settings

Key concepts: Spirometer, Spirometry, Medicine, Asthma, COPD, Peak flow meter, Gold standard (test), Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Peak-flow or portable spirometry as a replacement for Spirometry in the diagnosis of COPD and Asthma — Research Paper | ScholarLens