A Note on One- and Three-Dimensional Infiltration Analysis from a Mini Disc Infiltrometer
George Kargas, Paraskevi A. Londra, Konstantinos Anastasiou, Petros G. Kerkides
Abstract
Open-access reader
George Kargas, Paraskevi A. Londra, Konstantinos Anastasiou, Petros G. Kerkides
Abstract
Open-access reader
Disc infiltrometers are used to characterize soil hydraulic properties. The purpose of this study was to determine the difference between three- and one-dimensional infiltration and to calculate the infiltration shape parameter γ from a proposed analytical infiltration equation. One- and three-dimensional infiltration tests were done on three repacked soils (loam, sandy loam, and silty clay loam) for two negative pressure heads. A mini disc infiltrometer of a radius of 22.5 mm with suction that ranged from −5 mm to −70 mm was used. The difference between experimental three- and one-dimensional cumulative infiltration was linear with time, which confirmed the proposed equation. In this study, the shape parameter γ seems not to be seriously affected by the soil type and acquires values from 0.561 to 0.615, i.e., smaller than the value γ = 0.75, which is widely used. With these values, the criteria proposed for calculating hydraulic conductivity using three-dimensional infiltration data may be fulfilled in most soils.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Disc infiltrometers are used to characterize soil hydraulic properties. The purpose of this study was to determine the difference between three- and one-dimensional infiltration and to calculate the infiltration shape parameter γ from a proposed analytical infiltration equation. One- and three-dimensional infiltration tests were done on three repacked soils (loam, sandy loam, and silty clay loam) for two negative pressure heads. A mini disc infiltrometer of a radius of 22.5 mm with suction that ranged from −5 mm to −70 mm was used. The difference between experimental three- and one-dimensional cumulative infiltration was linear with time, which confirmed the proposed equation. In this study, the shape parameter γ seems not to be seriously affected by the soil type and acquires values from 0.561 to 0.615, i.e., smaller than the value γ = 0.75, which is widely used. With these values, the criteria proposed for calculating hydraulic conductivity using three-dimensional infiltration data may be fulfilled in most soils.
Key concepts: Infiltrometer, Loam, Infiltration (HVAC), Hydraulic conductivity, Soil water, Geotechnical engineering, Soil science, Mathematics