Liquid–Liquid Extraction of Yttrium(III) Using 2-Ethylhexyl Phosphonic Acid Mono-2-ethylhexyl (EHEHPA) in a Microreactor: A Comparative Study
Yuan He, Shenghui Guo, Muhammad Ibrar Khan, Kaihua Chen, Shiwei Li, Libo Zhang, Shaohua Yin
Abstract
Yuan He, Shenghui Guo, Muhammad Ibrar Khan, Kaihua Chen, Shiwei Li, Libo Zhang, Shaohua Yin
Abstract
Experiments were carried out in a slug flow microreactor to systematically investigate reaction behavior under variation of flow rate, and a comparative study was made. Y-junction microreactor and T-junction microreactor have been used to extract yttrium(III) using 2-ethylhexyl phosphonic acid mono-2-ethylhexyl (EHEHPA or P507). Results show that the maximum extraction efficiency of 90.4% in both microreactors could be achieved corresponding to the minimum flow rate of 10 and 100 μL/min. The values of specific interfacial area remain unchanged with the increase of flow rate, and the specific interfacial area of the Y-junction serpentine microreactor is much higher than that of the T-junction microreactor. Maximum values of volumetric mass-transfer coefficient (1.642 s –1 ) in the Y-junction microreactor are found to be several orders of magnitude higher than those of the T-junction microchannel (0.043 s –1 ) and conventional extractors (0.0197 s –1 ).
OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Experiments were carried out in a slug flow microreactor to systematically investigate reaction behavior under variation of flow rate, and a comparative study was made. Y-junction microreactor and T-junction microreactor have been used to extract yttrium(III) using 2-ethylhexyl phosphonic acid mono-2-ethylhexyl (EHEHPA or P507). Results show that the maximum extraction efficiency of 90.4% in both microreactors could be achieved corresponding to the minimum flow rate of 10 and 100 μL/min. The values of specific interfacial area remain unchanged with the increase of flow rate, and the specific interfacial area of the Y-junction serpentine microreactor is much higher than that of the T-junction microreactor. Maximum values of volumetric mass-transfer coefficient (1.642 s –1 ) in the Y-junction microreactor are found to be several orders of magnitude higher than those of the T-junction microchannel (0.043 s –1 ) and conventional extractors (0.0197 s –1 ).
Key concepts: Microreactor, Microchannel, Yttrium, Volumetric flow rate, Extraction (chemistry), Analytical Chemistry (journal), Chemistry, Materials science