Technological concentration sensor for ethanolamines based on an optical sensor

Aleksandr Maslennikov, И. Л. Зубков, Nikolai Peskov

Open full text 0 citations

Abstract

The most important parameters necessary for the precise control of the separation of monoethanolamine, diethanolamine, and triethanolamine on column distillation apparatus are their initial concentrations in the mixtures fed to the columns. Currently, the use of a solid-state optical sensor, which makes it possible to determine the desired ratio in a mode close to the real-time regime. The technical parameters for the sensitivity and speed achieved by the sensor are determined in the determination of monoethanolamine, diethanolamine, and triethanolamine, as well as the sensor parameters and conditions of use, which enable the sensor to effectively solve the tasks. In particular, the concentration of the mixture of analytes in the sensor chamber is 500 mg / m3, the thickness of the sensitive coating is about 0.5 μm, the operating temperature is 45÷50 ° C, the time for one cycle of measuring the diethanolamine/triethanolamine ratio is 150 ÷ 180 seconds.

Open-access reader

About this research paper

What this paper is about

The most important parameters necessary for the precise control of the separation of monoethanolamine, diethanolamine, and triethanolamine on column distillation apparatus are their initial concentrations in the mixtures fed to the columns. Currently, the use of a solid-state optical sensor, which makes it possible to determine the desired ratio in a mode close to the real-time regime. The technical parameters for the sensitivity and speed achieved by the sensor are determined in the determination of monoethanolamine, diethanolamine, and triethanolamine, as well as the sensor parameters and conditions of use, which enable the sensor to effectively solve the tasks. In particular, the concentration of the mixture of analytes in the sensor chamber is 500 mg / m3, the thickness of the sensitive coating is about 0.5 μm, the operating temperature is 45÷50 ° C, the time for one cycle of measuring the diethanolamine/triethanolamine ratio is 150 ÷ 180 seconds.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The most important parameters necessary for the precise control of the separation of monoethanolamine, diethanolamine, and triethanolamine on column distillation apparatus are their initial concentrations in the mixtures fed to the columns. Currently, the use of a solid-state optical sensor, which makes it possible to determine the desired ratio in a mode close to the real-time regime. The technical parameters for the sensitivity and speed achieved by the sensor are determined in the determination of monoethanolamine, diethanolamine, and triethanolamine, as well as the sensor parameters and conditions of use, which enable the sensor to effectively solve the tasks. In particular, the concentration of the mixture of analytes in the sensor chamber is 500 mg / m3, the thickness of the sensitive coating is about 0.5 μm, the operating temperature is 45÷50 ° C, the time for one cycle of measuring the diethanolamine/triethanolamine ratio is 150 ÷ 180 seconds.

Key concepts: Diethanolamine, Triethanolamine, Ethanolamines, Materials science, Analytical Chemistry (journal), Distillation, Chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Technological concentration sensor for ethanolamines based on an optical sensor — Research Paper | ScholarLens