2018•Indian Journal of OphthalmologyOpen access

Precision pulse capsulotomy in phacoemulsification: Clinical experience in Indian eyes

JaiA Kelkar, Hetal Mehta, AdityaS Kelkar, Aanchal A. Agarwal, AkshayA Kothari, ShreekantB Kelkar

Open full text 18 citations

Abstract

Purpose: To evaluate the surgical outcome of precision pulse capsulotomy (PPC) in phacoemulsification surgery. Methods: One hundred twenty-three eyes of 99 consecutive patients who underwent phacoemulsification with PPC through a 2.8 mm clear corneal incision were prospectively studied at a tertiary care centre. The size, shape of capsulotomy and intraoperative capsulotomy, and surgery-related complications were noted. Visual outcome, IOL stability, and signs of capsular opacification/contraction were evaluated at 3 and 6 months. Results: The mean age of patients was 49.5 ± 7.77 years. Complete, circular capsulotomy averaging 5.5 mm diameter was achieved in 117 of 123 eyes. In seven eyes, we experienced complications like capsulorhexis tear (n = 6) and inadvertent iris capture (n = 1). Probe malfunction occurred in six cases. Stable intracapsular intraocular lens (IOLs) fixation and centration was achieved in all eyes. None of the eyes had any significant posterior capsular opacification or capsular contraction at 3 and 6 months. In one eye anterior capsular opacification at the capsulotomy edge was noted at 6 months. Conclusion: PPC is a useful device for achieving a perfectly round capsulorrhexis. However, it has a learning curve and chances of skip areas in capsulorhexis, capsular tag, and its extension should be kept in mind. Special care should be taken in initial cases and while operating on eyes with poorly dilating pupil and mature cataracts.

About this research paper

What this paper is about

Purpose: To evaluate the surgical outcome of precision pulse capsulotomy (PPC) in phacoemulsification surgery. Methods: One hundred twenty-three eyes of 99 consecutive patients who underwent phacoemulsification with PPC through a 2.8 mm clear corneal incision were prospectively studied at a tertiary care centre. The size, shape of capsulotomy and intraoperative capsulotomy, and surgery-related complications were noted. Visual outcome, IOL stability, and signs of capsular opacification/contraction were evaluated at 3 and 6 months. Results: The mean age of patients was 49.5 ± 7.77 years. Complete, circular capsulotomy averaging 5.5 mm diameter was achieved in 117 of 123 eyes. In seven eyes, we experienced complications like capsulorhexis tear (n = 6) and inadvertent iris capture (n = 1). Probe malfunction occurred in six cases. Stable intracapsular intraocular lens (IOLs) fixation and centration was achieved in all eyes. None of the eyes had any significant posterior capsular opacification or capsular contraction at 3 and 6 months. In one eye anterior capsular opacification at the capsulotomy edge was noted at 6 months. Conclusion: PPC is a useful device for achieving a perfectly round capsulorrhexis. However, it has a learning curve and chances of skip areas in capsulorhexis, capsular tag, and its extension should be kept in mind. Special care should be taken in initial cases and while operating on eyes with poorly dilating pupil and mature cataracts.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To evaluate the surgical outcome of precision pulse capsulotomy (PPC) in phacoemulsification surgery. Methods: One hundred twenty-three eyes of 99 consecutive patients who underwent phacoemulsification with PPC through a 2.8 mm clear corneal incision were prospectively studied at a tertiary care centre. The size, shape of capsulotomy and intraoperative capsulotomy, and surgery-related complications were noted. Visual outcome, IOL stability, and signs of capsular opacification/contraction were evaluated at 3 and 6 months. Results: The mean age of patients was 49.5 ± 7.77 years. Complete, circular capsulotomy averaging 5.5 mm diameter was achieved in 117 of 123 eyes. In seven eyes, we experienced complications like capsulorhexis tear (n = 6) and inadvertent iris capture (n = 1). Probe malfunction occurred in six cases. Stable intracapsular intraocular lens (IOLs) fixation and centration was achieved in all eyes. None of the eyes had any significant posterior capsular opacification or capsular contraction at 3 and 6 months. In one eye anterior capsular opacification at the capsulotomy edge was noted at 6 months. Conclusion: PPC is a useful device for achieving a perfectly round capsulorrhexis. However, it has a learning curve and chances of skip areas in capsulorhexis, capsular tag, and its extension should be kept in mind. Special care should be taken in initial cases and while operating on eyes with poorly dilating pupil and mature cataracts.

Key concepts: Capsulorhexis, Medicine, Phacoemulsification, Capsulotomy, Ophthalmology, Centration, Intraocular lens, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Precision pulse capsulotomy in phacoemulsification: Clinical experience in Indian eyes — Research Paper | ScholarLens